Abstract

Objective The commercially available C-Port distal anastomotic device (Food and Drug Administration cleared in 2007) is an automated miniature vascular stapler that performs the coronary anastomosis. This prospective multicenter registry sought to evaluate midterm patency using this device compared with hand-sewn grafts. Methods Patients receiving at least one C-Port anastomosis during coronary artery bypass grafting surgery were enrolled at eight sites. Of the 117 patients enrolled, 78 patients (67%) with 104 C-Port vein grafts completed the study to patency assessment via computed tomography angiography. Clinical follow-up and index graft patency (Gated 64-slice computed tomography scan) were performed at least 12 months postoperatively. The primary efficacy endpoint was patency compared with the peer-reviewed results from the PRoject of Ex-vivo Vein graft ENgineering via Transfection IV (PREVENT IV) trial. Results The patient population was consistent with the PREVENT IV placebo cohort. The mortality at 12 months was 0.85% (1/117). The major cardiac morbidity rate was 3.4% (4/117). The C-Port vein graft occlusion rate was 16.3% (17/104) compared with 26.6% (597/2242) in the PREVENT IV trial ( P = 0.011). Within this study, C-Port graft occlusion rates were not significantly different from the hand-sewn grafts ( P = 0.821). Conclusions The C-Port device is safe and effective in creating the distal anastomosis with equivalent patency rates to hand-sewn grafts at 12 months. When compared with hand-sewn anastomoses from a recent large prospective trial, the C-Port device demonstrated a statistically significant reduction in midterm graft occlusion. Further studies are required to evaluate its effect in less invasive coronary surgery.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

Cited by 16 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3