Safety and Functionality of a Guidewire Fixator

Author:

Liungman Krister1,Mani Kevin1,Wanhainen Anders1,Bosaeus Linus2,Lachat Mario3

Affiliation:

1. Department of Surgical Sciences, Uppsala University, Uppsala, Sweden

2. Endovascular Development Ltd, Uppsala, Sweden

3. Universitätskrankenhaus Zurich, Zurich, Switzerland.

Abstract

Objective A new endovascular tool, the Liungman Guidewire Fixator, has been developed to simplify endovascular treatment in complex aortic aneurysms. The device has been extensively tested in bench models and animal trials. To verify the safety and functionality demonstrated in the porcine model, the device was tested in ten patients undergoing endovascular aortic repair (EVAR) or fenestrated endovascular aortic repair (f-EVAR) treatment for abdominal aortic aneurysm. Methods The Liungman Guidewire Fixator consists of a braided stent-like, cylindrical structure with conical ends and a central channel for a 0.035” guidewire. When in use, it is slid along the guidewire and positioned in the target artery, where the Liungman Guidewire Fixator interacts with the arterial wall by anchoring the guidewire to the wall through a radial force. The Liungman Guidewire Fixator allows for uninterrupted blood flow passed the point of fixation. In this study, the Liungman Guidewire Fixator was tested in ten patients undergoing EVAR or f-EVAR treatment for abdominal aortic aneurysm. The device was deployed and retrieved crossover into the hypogastric artery, and the occurrence of thrombotic occlusion, arterial dissection, and vascular rupture or trauma was studied using angiography, as well as device ability to withstand guidewire tension. Results There were no instances of occlusion, dissection, or vascular trauma detected using angiography. In all cases, deployment and retrieval were successful, and the devices could withstand an applied tension of 3 N. In one instance, retrieval was challenging because of significant tortuosity, which was resolved by a coaxial catheterization. Conclusions Deployment was uneventful in all ten patients. Retrieval according to the intended instruction for use was performed in nine of the patients. In one patient, a coaxial catheterization was necessary. All devices withstood a retention force of 3 N.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine,Surgery,Pulmonary and Respiratory Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3