Microvascular abnormalities induced by hand-transmitted vibration reflects in finger systolic blood pressure: a cross-sectional study in China

Author:

Yan Maosheng12,Zheng Hanjun12,Liu Qian3,Xiao Bin1,Wang Chengmin4,Jia Yanxia5,Pan Siyu16

Affiliation:

1. Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangdong Provincial Key Laboratory of Occupational Disease Prevention and Treatment

2. Department of Public Health, Guangzhou Medical University, Guangzhou, Guangdong

3. Department of Public Health, Southeast University, Nanjing, Jiangsu

4. Department of Public Health, Anhui Medical University, Hefei, Anhui

5. Department of Public Health, Shanxi Medical University, Tai Yuan, Shanxi

6. Department of Public Health, Guangdong Pharmaceutical University, Guangzhou, Guangdong

Abstract

Objective Local vibration can cause microcirculatory abnormalities such as blood stasis and symmetrical intermittent digital artery vasospasm. Finger SBP (FSBP) measurement is a potential way of assessing vascular components. This study aims to comprehensively investigate the relationship between the occurrence of the vibration-induced white finger (VWF) and changes in FSBP and then set the application value of FSBP measurements in the early diagnosis of VWF. Methods All samples were judgmental sampling from one factory. Totally 50 patients with VWF were the case group, while 50 without occupational hand-transmitted vibration exposure were the control group. FSBP measurements and epidemiological feature investigations were taken. Results There were significant reductions in FSBP level and %FSBP index at both 10 °C and 30 °C in fingers reported VWF (P < 0.05). The %FSBP abnormal rate of the index, ring and little finger in the VWF group was higher than the control (44.00% vs. 18.00%, 78.00% vs. 26.00%, 64.00% vs. 8.00%). The %FSBP of the ring and little finger had a relatively high application value (area under curve = 0.902, 0.737), while their standard regression coefficients were −0.23 and −0.412. The diagnostic cutoff value of the ring finger was 77.60%, while the sensitivity and specificity were 86.67%. Conclusion FSBP measurements were proven helpful in monitoring and diagnosing VWF prospectively and proved to have great application value in our study. %FSBP of the ring finger was the appropriate diagnostic index in FSBP measurements, while its abnormal value could be set as 80.00%.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3