A clinical validation of AViTA home blood pressure monitor for atrial fibrillation detection in adults

Author:

Chiu Fu-Chun1,Huang I-Chih2

Affiliation:

1. Division of Cardiology, Department of Internal Medicine, National Taiwan University Hospital, and National Taiwan University College of Medicine, Yun-Lin Branch, Douliu City, Yunlin County

2. R&D Software Department, AViTA Corporation, Taipei, Taiwan

Abstract

Background Atrial fibrillation (AF) is a stroke and heart complication riskbut is often overlooked due to subtle symptoms. The accessibility of sphygmomanometers that can detect AF, may play crucial roles in identifying asymptomatic patients. AViTA BPM63B is an automatic blood pressure (BP) monitor for atrial fibrillation detection. This study validated the performance of BPM63B for AF detection using two novel algorithms of time-domain analysis and frequency-domain analysis which evaluate multiple statistics. Methods The study included 100 subject, with 47 participants being male (47%) and ages ranging from 24 to 89 years (mean ± SD: 59 ± 17 years). Each participant received three consecutive readings from the subject device and a 12-lead ECG assessment. The pulse wave data from subject device was analyzed using the two algorithms. The atrial fibrillation status thus determined was compared to the ECG results interpreted by a physician. Results Among the 100 participants, 52 patients had chronic atrial fibrillation, along with 48 outpatients exhibiting sinus rhythm or non-atrial fibrillation arrhythmias. Using the time-domain analysis method for atrial fibrillation detection, we achieved a sensitivity of 94.8% [95% confidence interval (CI), 90.08–97.75%] and a specificity of 98.6% (95% CI, 95.07–99.83%). Similarly, utilizing the frequency-domain analysis method resulted in a sensitivity of 91.6% (95% CI, 86.08–95.46%) and specificity of 94.4% (95% CI, 89.35–97.57%). Conclusions These findings suggest that AViTA BPM63B, which integrates two novel algorithms for atrial fibrillation diagnosis, demonstrates high sensitivity and specificity. Utilizing the AViTA BPM63B for BP monitoring could aid in the early detection of atrial fibrillation among outpatients in cardiology clinics.

Funder

Conventional Industry Technology Development

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3