Affiliation:
1. Department of Plastic and Reconstructive Surgery, Johns Hopkins School of Medicine
2. Division of Plastic and Reconstructive Surgery, Washington University in St. Louis School of Medicine.
Abstract
Background:
Breast implants are the most commonly used medical devices in plastic surgery, and capsular contracture (CC) is one of the most common complications. However, our assessment of CC is based largely on Baker grade, which is problematically subjective and affords only four possible values.
Methods:
The authors performed a systematic review concluding in September of 2021 in compliance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. It identified 19 articles that propose approaches to measuring CC.
Results:
In addition to Baker grade, the authors identified several modalities reported to measure CC. These included magnetic resonance imaging, ultrasonography, sonoelastography, mammacompliance measuring devices, applanation tonometry, histologic evaluation, and serology. Capsule thickness and other measures of CC inconsistently correlated with Baker grade, whereas the presence of synovial metaplasia was consistently associated with Baker grade I and II, but not III and IV capsules.
Conclusions:
There remains no particular method to reliably and specifically measure the contracture of capsules that form around breast implants. As such, we would recommend that research investigators use more than one modality to measure CC. Other variables that can impact breast implant stiffness and associated discomfort beyond CC need to be considered when evaluating patient outcomes. Given the value placed on CC outcomes in assessing breast implant safety, and the prevalence of breast implants overall, the need for a more reliable approach to measuring this outcome persists.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Cited by
8 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献