Application of a Microsuction Background Device for Microanastomosis in a Rat Femoral Vessel Model

Author:

Khajuria Ankur12,Jeong Hyung Hwa3,Papavasiliou Theodora4,Chatzimichail Stelios5,Hong Joon Pio3

Affiliation:

1. Kellogg College

2. Department of Surgery and Cancer, Imperial College London

3. Department of Plastic Surgery, Asan Medical Centre, University of Ulsan College of Medicine

4. Department of Plastic Surgery, John Radcliffe Hospital.

5. Biological Physics Research Group, University of Oxford

Abstract

Summary: Microvascular anastomoses can be challenging to perform when edematous fluids and blood continuously flood and compromise the field of view. Intermittent irrigation and suctioning disturb workflow, require an assistant, and can increase risk of arterial thrombosis from vessels being drawn into suction drains. The authors developed and patented a novel three-dimensionally printed background device with microfluidic capabilities to provide autonomous, continuous irrigation and suction to optimize operator autonomy and efficiency. The authors tested this in a rat femoral vessel model. Twelve end-to-end anastomoses were performed by two senior microsurgeons [six conventional, six suction-assisted background (SAB)] in a rat femoral artery model. The primary outcome was time taken to complete the anastomosis. Secondary outcomes included the validated Structured Assessment of Microsurgery Skills (SAMS) score and the total number of “wiping” events to obtain field clarity. Each procedure was recorded, and videos were independently rated by two blinded experts using the SAMS score. Time taken to complete the anastomosis was greater in the conventional group compared with the SAB group (741.7 ± 203.1 seconds versus 584 ± 155.9 seconds; P = 0.007). The median SAMS score was lower in the conventional group compared with the SAB group (32.3 ± 1.4 versus 38.3 ± 1.5; P = 0.001). The median number of wiping events was significantly greater in the conventional group compared with the SAB group (13 ± 2.2 versus 1.7 ± 1.2; P < 0.001). The authors show that a novel microfluidic background device allows continuous irrigation and suctioning without the need for an assistant, optimizing the efficiency of the microvascular anastomosis. Clinical Relevance Statement: The authors have designed a novel, patented, three-dimensionally printed microsurgical background device that provides continuous irrigation and suction, reduces operative time, and provides better vessel clarity during a microsurgical anastomosis compared to standard background.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. A Simple, Cost-effective Microsuction Device;Plastic and Reconstructive Surgery - Global Open;2023-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3