Improving Pediatric Ovarian Torsion Evaluation in the Pediatric Emergency Department: A Quality Improvement Initiative

Author:

Park Brian L.1,Fenstermacher Sara1,Stanescu A. Luana2,Rutman Lori1,Kinneman Lauren1,Solari Patrick1

Affiliation:

1. Department of Pediatrics, Division of Emergency Medicine, Seattle Children’s Hospital, University of Washington School of Medicine, Seattle, CA, USA

2. Department of Radiology, Seattle Children’s Hospital, University of Washington School of Medicine, Seattle, CA, USA.

Abstract

Background: Transabdominal pelvic ultrasound (TPUS) is the diagnostic test of choice for the evaluation of ovarian torsion, a time-sensitive surgical emergency. A full bladder is required to visualize the ovaries. Bladder filling is a time-consuming process leading to delays to TPUS, poor visualization of ovaries requiring repeat studies, and prolonged emergency department length of stay (ED LOS). The primary objective was to decrease the time to TPUS by standardizing the bladder filling process. Methods: This quality improvement initiative occurred at a single, academic, quaternary-care children’s hospital ED and utilized the Institute for Healthcare Improvement Model for Improvement with sequential plan-do-study-act cycles. The first set of interventions implemented in August 2021 included a new electronic order set and bladder scan by ED nurses. Subsequent plan-do-study-act cycles aimed to decrease the time to intravenous fluid, decrease fluid requirement, and decrease the need for intravenous fluid. The primary outcome measure was the monthly mean time to TPUS. Secondary outcome measures included monthly mean ED LOS and percentage of repeat TPUS. We performed data analysis with statistical process control charts to assess for system change over time. Results: The preintervention baseline included 292 ED encounters more than 10 months, and postintervention analysis included 526 ED encounters more than 16 months. Time to TPUS decreased (138–120 min), ED LOS decreased (372–335 min), and repeat TPUS decreased (18% to 4%). All changes met the rules for special cause variation. Conclusions: Standardizing the bladder filling process was associated with decreased time to TPUS, ED LOS, and repeat TPUS.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Pediatrics, Perinatology and Child Health

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3