Modified Tap-drilling Technique for Mid-cervical Pedicle Screw Placement

Author:

Sucu Hasan Kâmil1,Sevin İsmail Ertan1,Gürkan Gökhan2

Affiliation:

1. Department of Neurosurgery, İzmir Kâtip Çelebi University, Atatürk Research and Training Hospital

2. Department of Neurosurgery, İzmir Atatürk Research and Training Hospital, İzmir, Turkey

Abstract

Study Design: Retrospective cohort study. Objection: To report our modified tap-drilling technique for mid-cervical pedicle screw placement and to evaluate its safety and accuracy. Summary of Background Data: Cervical pedicle screw fixation, which provides a strong stabilization, has been a major concern due to the potential risks to neurovascular structures despite its increasing use. Several insertion techniques have been described so far to improve the cervical pedicle screw placement accuracy. Methods: This study retrospectively reviewed patients who underwent mid-cervical (C3–C6) pedicle screw fixation between September 2005 and September 2020. Laminectomy, laminoforaminotomy, or notch-referred anatomic landmark methods were used to adjust the entry point and the direction of the screws. After the cortical bone was removed at the entry point with a diamond burr, the cancellous bone was slowly drilled with a hand drill starting from 8 to 10 millimeters in length. Then, all of the bone walls were checked with a ball-tip probe to determine if there was any breach. The procedure was repeated several times. After completing the drilling, the screw was inserted without tapping. The breach rate of pedicle screws was analyzed on postoperative computed tomography scans. Results: A total of 473 mid-cervical pedicle screws were placed in 122 consecutive patients. No navigation or computer-assisted system was used, and the first 2 authors inserted all of the screws. All patients completed the surgery, and no evident intraoperative complications occurred. Postoperative CT scans were obtained for 405 screws. Although deviation was observed for 131 pedicle screws, a critical deviation was observed for only 25 pedicle screws. Conclusions: Cervical pedicle screw insertion is a risky but applicable technique. Checking all of the bone walls with a ball-tip probe before gradually advancing the hand drill in small amounts, as presented in this article, may lead to the safe and effective placement of cervical pedicle screws.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3