A Prospective Cohort Study of Radiation Exposure to a Spine Surgeon’s Exposed Body Parts During Utilization of Intraoperative Radiation-based Imaging

Author:

Chauhan DakshORCID,Ahmad Hasan S.,Singh Shikha,Albayar Ahmed,Patel Arjun,Welch William C.,Yoon Jang W.

Abstract

Study Design: Prospective cohort study. Summary of Background Data: C-arm fluoroscopy and O-arm navigation are vital tools in modern spine surgeries, but their repeated usage can endanger spine surgeons. Although a surgeon’s chest and abdomen are protected by lead aprons, the eyes and extremities generally receive less protection. Objective: In this study, we compare differences in intraoperative radiation exposure across the protected and unprotected regions of a surgeon’s body. Methods: Sixty-five consecutive spine surgeries were performed by a single spine-focused neurosurgeon over 9 months. Radiation exposure to the primary surgeon was measured through dosimeters worn over the lead apron, under the lead apron, on surgical loupes, and as a ring on the dominant hand. Differences were assessed with rigorous statistical testing and radiation exposure per surgical case was extrapolated. Results: During the study, the measured radiation exposure over the apron, 176 mrem, was significantly greater than that under the apron, 8 mrem (P = 0.0020), demonstrating a shielding protective effect. The surgeon’s dominant hand was exposed to 329 mrem whereas the eyes were exposed to 152.5 mrem of radiation. Compared with the surgeon’s protected abdominal area, the hands (P = 0.0002) and eyes (P = 0.0002) received significantly greater exposure. Calculated exposure per case was 2.8 mrem for the eyes and 5.1 mrem for the hands. It was determined that a spine-focused neurosurgeon operating 400 cases annually will incur a radiation exposure of 60,750 mrem to the hands and 33,900 mrem to the eyes over a 30-year career. Conclusions: Our study found that spine surgeons encounter significantly more radiation exposure to the eyes and the extremities compared with protected body regions. Lifetime exposure exceeds the annual limits set by the International Commission on Radiologic Protection for the extremities (50,000 mrem/y) and the eyes (15,000 mrem/y), calling for increased awareness about the dangerous levels of radiation exposure that a spine surgeon incurs over one’s career.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3