Routine MRI Among Patients With a Suspected Scaphoid Fracture Risks Overdiagnosis

Author:

Bulstra Anne Eva J.12ORCID,van Boxel Marouska F.12,Crijns Tom J.3,Kelly Joshua1,Obdeijn Miryam C.4,Kerkhoffs Gino M. M. J.2,Doornberg Job N.12,Ring David3,Jaarsma Ruurd L.1

Affiliation:

1. Department of Orthopedic and Trauma Surgery, Flinders Medical Centre, Bedford Park, South Australia, Australia

2. Department of Orthopaedic Surgery, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands

3. Department of Surgery and Perioperative Care, Dell Medical School, the University of Texas at Austin, Austin, TX, USA

4. Department of Plastic, Reconstructive and Hand Surgery, Amsterdam UMC, University of Amsterdam, Amsterdam, the Netherlands

Abstract

Abstract Background In the setting of a suspected scaphoid fracture, MRI may result in overdiagnosis and potential overtreatment. This is in part because of the low prevalence of true fractures among suspected fractures, but also because of potentially misleading variations in signal that may be more common than fracture-related signal changes. To better understand the risk of overdiagnosis, we first need insight into the relative prevalence of useful and potentially distracting signal changes among patients with a suspected scaphoid fracture. Question/purpose What is the proportion of signal changes representing definite and possible scaphoid fractures relative to other types of signal changes on MRI among patients with a suspected scaphoid fracture? Methods In a retrospective study in an orthopaedic trauma clinic associated with a Level I trauma center, we evaluated MR images of patients 16 years and older with a clinically suspected scaphoid fracture. At our institution, patients with symptoms and signs of a possible scaphoid fracture and negative radiographs undergo MRI scanning. Between January 1, 2012, and September 1, 2019, a total of 310 patients 16 years or older had an MRI to evaluate a suspected scaphoid fracture. Exclusion criteria included a scaphoid fracture that was visible on radiographs before MRI as reported by the radiologist (four patients), no available radiographs before MRI (two), MRI more than 3 weeks after injury (28), unknown date of injury (nine), and repeat or bilateral MRI scans (11), leaving 256 MR images for analysis. Sixty percent (153) of patients were women, and the median age was 34 years (IQR 21 to 50 years). The images were taken a median of 8 days (IQR 2 to 12 days) after injury. MR images were screened for the presence of scaphoid signal changes. We identified the following patterns of signal change with a reliability of kappa 0.62: definite scaphoid fracture, possible scaphoid fracture, signal in the waist area other than possible or definite fractures, and other signal changes. A definite scaphoid fracture was defined as a linear, focal, and bicortical signal abnormality, with adjacent edema and a relatively transverse orientation relative to the scaphoid long axis. The transverse linear signal was visible on more than one cut in multiple planes. A possible scaphoid fracture had a transverse linear signal on more than one cut on sagittal or coronal planes, with or without adjacent edema. Results Six percent (16 of 256) of MR images were categorized as revealing definite (2% [four of 256]) or possible (5% [12 of 256]) scaphoid fractures, whereas 29% (74 of 256) were categorized as revealing nonspecific signal changes at the waist (14% [35 of 256]) and other areas (15% [39 of 256]). Of the 51 patients with scaphoid waist signal changes, 69% (35) were categorized as having distracting and potentially misleading MRI findings. Conclusion The high prevalence of signal changes that are distracting and potentially misleading, the low prevalence of signal changes that clearly represent a scaphoid fracture, and the low pretest odds of a true fracture among patients with a suspected scaphoid fracture illustrate that routine MRI of suspected scaphoid fractures carries a notable risk of overdiagnosis and potential overtreatment. Two alternative strategies are supported by preliminary evidence and merit additional attention: more-selective use of MRI in people deemed at higher risk according to a clinical prediction rule and strategies for involving the patient in decisions regarding how to manage the notably small risk of future symptomatic nonunion. Level of Evidence Level IV, diagnostic study.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3