A Nomogram That Characterizes a Patient’s Odds of Developing Squeaking After Fourth-generation Ceramic-on-ceramic THA

Author:

Li Zhuo12,Niu Er-Long23,Fu Jun24,Zhou Yong-Gang24,Chai Wei24,Hao Li-Bo24,Chen Ji-Ying24,Xu Chi24

Affiliation:

1. School of Medicine, Nankai University, Tianjin, PR China

2. Department of Orthopedics, The First Medical Center, Chinese PLA General Hospital, Beijing, PR China

3. 305 Hospital of PLA, Beijing, PR China

4. Department of Orthopedics, The Fourth Medical Center, Chinese PLA General Hospital, Beijing, PR China

Abstract

Abstract Background Although ceramic-on-ceramic (CoC) bearings result in the lowest wear rate of any bearing combination, postoperative squeaking remains worrisome. However, data concerning squeaking in long-term follow-up studies are still lacking, especially for fourth-generation CoC THA. Questions/purposes (1) After keeping the prosthesis in place for 10 years, what percentage of patients treated with fourth-generation CoC THA implants report squeaking, and are there points in time when squeaking occurs more frequently? (2) What are the characteristics, association with hip function, and factors associated with squeaking? (3) Can we create a nomogram that characterizes a patient’s odds of experiencing squeaking based on the factors associated with it? Methods Between January 2009 and December 2011, 1050 patients received primary THAs at our institution, 97% (1017) of whom received fourth-generation CoC THAs because this was the preferred bearing during this period. Of the 1017 eligible patients, 5% (54) underwent THAs performed by low-volume surgeons, 3% (30) were implanted with cemented prostheses, 2% (22) died, 1% (10) were immobile, 1% (six) underwent revision surgery, and 17% (169) were lost to follow-up before 10 years, leaving 726 patients for analysis here at a mean of 11 ± 1 years. In the study cohort, 64% (464) were male and 36% (262) were female, with a mean age of 44 ± 13 years at primary THA. We extracted data about articular noise from follow-up records in our institutional database and used a newly developed questionnaire to ascertain the percentage of patients who reported squeaking at the latest follow-up interval. Although not validated, the questionnaire was modeled on previous studies on this topic. The longitudinal pattern for squeaking was explored to find timepoints when squeaking occurs more frequently. Based on the questionnaire data, we calculated the percentages of frequent, reproducible, and avoidable squeaking. Hip function was evaluated with the Harris Hip Score and WOMAC score and compared between the squeaking and nonsqueaking groups. Factors associated with squeaking, which were examined in a multivariate analysis, were used to develop a nomogram. Results At 10 years, 16% (116 of 726) of patients reported squeaking. Two squeaking peaks were determined, at 0 to 1 year and 8 to 10 years. Frequent, reproducible, and avoidable squeaking accounted for 42% (36 of 86), 20% (17 of 86), and 41% (35 of 86), respectively. The mean Harris Hip Score (93 ± 4 versus 94 ± 5; p = 0.81) and WOMAC score (16 ± 13 versus 15 ± 13; p = 0.23) did not differ between patients with squeaking and those without. After controlling for potential confounding variables such as etiology and head offset, we found that patients younger than 46 years (odds ratio 2.5 [95% confidence interval 1.5 to 5.0]; p < 0. 001), those who were male (OR 2.0 [95% CI 1.1 to 3.5]; p = 0.04), those having a total flexion and extension arc of less than 50° (OR 2.0 [95% CI 1.2 to 3.3]; p = 0.02), and those with the Corail hip implant (OR 4.1 [95% CI 2.1 to 7.7]; p < 0. 001) were more likely to report squeaking. We created a nomogram that can be used at the point of care that can help clinicians identify patients at a higher risk of experiencing squeaking; this nomogram had good performance (area under the receiver operating characteristic curve of 77%). Conclusion As a potential late complication, squeaking after fourth-generation CoC THA is of concern and may be related to increased stripe wear. We recommend that surgeons use this nomogram to assess the odds of squeaking before selecting a bearing, especially in patients at high risk, to facilitate shared decision-making and improve patient satisfaction. Future external validation of the model is still needed to enhance its applicability. Level of Evidence Level III, therapeutic study.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3