How Do Standing Neutral, Supine Lateral, Standing Flexion, and Standing Extension Radiographs Compare in Detecting the Presence and Magnitude of Stable and Dynamic Spondylolisthesis?

Author:

Thompson Austin R.1ORCID,Montgomery Tyler P.12,Gillis Cai1,Smith Sawyer G.3,Carlson Nels L.1,Ensrud Erik R.1,Carlson Hans L.1,Marshall Lynn M.1,Yoo Jung U.1

Affiliation:

1. Department of Orthopaedics and Rehabilitation, Oregon Health & Science University, Portland, OR, USA

2. Charles E. Schmidt College of Medicine, Florida Atlantic University, Boca Raton, FL, USA

3. Department of Surgery, Oregon Health & Science University, Portland, OR, USA

Abstract

Abstract Background Clinical guidelines recommend standing radiographs as the most appropriate imaging for detecting degenerative spondylolisthesis, although reliable evidence about the standing position is absent. To our knowledge, no studies have compared different radiographic views and pairings to detect the presence and magnitude of stable and dynamic spondylolisthesis. Questions/purposes (1) What is the percentage of new patients presenting with back or leg pain with stable (3 mm or greater listhesis on standing radiographs) and dynamic (3 mm or greater listhesis difference on standing-supine radiographs) spondylolisthesis? (2) What is the difference in the magnitude of spondylolisthesis between standing and supine radiographs? (3) What is the difference in the magnitude of dynamic translation among flexion-extension, standing-supine, and flexion-supine radiographic pairs? Methods This cross-sectional, diagnostic study was performed at an urban, academic institution between September 2010 and July 2016; 579 patients 40 years or older received a standard radiographic three-view series (standing AP, standing lateral, and supine lateral radiographs) at a new patient visit. Of those individuals, 89% (518 of 579) did not have any of the following: history of spinal surgery, evidence of vertebral fracture, scoliosis greater than 30°, or poor image quality. In the absence of a reliable diagnosis of dynamic spondylolisthesis using this three-view series, patients may have had flexion and extension radiographs, and approximately 6% (31 of 518) had flexion and extension radiographs. A total of 53% (272 of 518) of patients were female, and the patients had a mean age of 60 ± 11 years. Listhesis distance (in mm) was measured by two raters as displacement of the posterior surface of the superior vertebral body in relation to the posterior surface of the inferior vertebral body from L1 to S1; interrater and intrarater reliability, assessed with intraclass correlation coefficients, was 0.91 and 0.86 to 0.95, respectively. The percentage of patients with and the magnitude of stable spondylolisthesis was estimated on and compared between standing neutral and supine lateral radiographs. The ability of common pairs of radiographs (flexion-extension, standing-supine, and flexion-supine) to detect dynamic spondylolisthesis was assessed. No single radiographic view or pair was considered the gold standard because stable or dynamic listhesis on any radiographic view is often considered positive in clinical practice. Results Among 518 patients, the percentage of patients with spondylolisthesis was 40% (95% CI 36% to 44%) on standing radiographs alone, and the percentage of patients with dynamic spondylolisthesis was 11% (95% CI 8% to 13%) on the standing-supine pair. Standing radiographs detected greater listhesis than supine radiographs did (6.5 ± 3.9 mm versus 4.9 ± 3.8 mm, difference 1.7 mm [95% CI 1.2 to 2.1 mm]; p < 0.001). Among 31 patients, no single radiographic pairing identified all patients with dynamic spondylolisthesis. The listhesis difference detected between flexion-extension was no different from the listhesis difference detected between standing-supine (1.8 ± 1.7 mm versus 2.0 ± 2.2 mm, difference 0.2 mm [95% CI -0.5 to 1.0 mm]; p = 0.53) and flexion-supine (1.8 ± 1.7 mm versus 2.5 ± 2.2 mm, difference 0.7 mm [95% CI 0.0 to 1.5]; p = 0.06). Conclusion This study supports current clinical guidelines that lateral radiographs should be obtained with patients in the standing position, because all cases of stable spondylolisthesis of 3 mm or greater were detected on standing radiographs alone. Each radiographic pair did not detect different magnitudes of listhesis, and no single pair detected all cases of dynamic spondylolisthesis. Clinical concern for dynamic spondylolisthesis may justify standing neutral, supine lateral, standing flexion, and standing extension views. Future studies could identify and evaluate a set of radiographic views that provides the greatest capacity to diagnose stable and dynamic spondylolisthesis. Level of Evidence Level III, diagnostic study.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3