What is the Safe Distance Between Hip and Knee Implants to Reduce the Risk of Ipsilateral Metachronous Periprosthetic Joint Infection?

Author:

Akkaya Mustafa12,Vles Georges3,Sangaletti Rudy1,Zanna Luigi1ORCID,Gehrke Thorsten1,Citak Mustafa1

Affiliation:

1. Department of Orthopaedic Surgery, HELIOS ENDO-Klinik Hamburg, Hamburg, Germany

2. Department of Orthopaedics and Traumatology, Ankara Yildirim Beyazit University, Ankara, Turkey

3. Department of Orthopaedic Surgery, UZ Leuven, Leuven, Belgium

Abstract

Abstract Background Periprosthetic joint infection (PJI), the most common cause of revision after TKA and THA, is a devastating complication for patients that is difficult to diagnose and treat. An increase in the number of patients with multiple joint arthroplasties in the same extremity will result in an increased risk of ipsilateral PJI. However, there is no definition of risk factors, micro-organism patterns, and safe distance between knee and hip implants for this patient group. Questions/purposes (1) In patients with hip and knee arthroplasties on the same side who experience a PJI of one implant, are there factors associated with the development of subsequent PJI of the other implant? (2) In this patient group, how often is the same organism responsible for both PJIs? (3) Is a shorter distance from an infected prosthetic joint to an ipsilateral prosthetic joint associated with greater odds of subsequent infection of the second joint? Methods We designed a retrospective study of a longitudinally maintained institutional database that identified all one-stage and two-stage procedures performed for chronic PJI of the hip and knee at our tertiary referral arthroplasty center between January 2010 and December 2018 (n = 2352). Of these patients, 6.8% (161 of 2352) had an ipsilateral hip or knee implant in situ at the time of receiving surgical treatment for a PJI of the hip or knee. The following criteria led to the exclusion of 39% (63 of 161) of these patients: 4.3% (seven of 161) for incomplete documentation, 30% (48 of 161) for unavailability of full-leg radiographs, and 5% (eight of 161) for synchronous infection. With regard to the latter, per internal protocol, all artificial joints were aspirated before septic surgery, allowing us to differentiate between synchronous and metachronous infection. The remaining 98 patients were included in the final analysis. Twenty patients experienced ipsilateral metachronous PJI during the study period (Group 1) and 78 patients did not experience a same-side PJI (Group 2). We analyzed the microbiological characteristics of bacteria during the first PJI and ipsilateral metachronous PJI. Calibrated, full-length plain radiographs were evaluated. Receiver operating characteristic curves were analyzed to determine the optimal cutoff for the stem-to-stem and empty native bone distance. The mean time between the initial PJI and ipsilateral metachronous PJI was 8 ± 14 months. Patients were followed for a minimum of 24 months for any complications. Results The risk of ipsilateral metachronous PJI in the other joint secondary to a joint implant in which PJI develops can increase up to 20% in the first 2 years after the procedure. There was no difference between the two groups in age, sex, initial joint replacement (knee or hip), and BMI. However, patients in the ipsilateral metachronous PJI group were shorter and had a lower weight (1.6 ± 0.1 m and 76 ± 16 kg). An analysis of the microbiological characteristics of bacteria at the time of the initial PJI showed no differences in the proportions of difficult-to-treat, high virulence, and polymicrobial infections between the two groups (20% [20 of 98] versus 80% [78 of 98]). Our findings showed that the ipsilateral metachronous PJI group had a shorter stem-to-stem distance, shorter empty native bone distance, and a higher risk of cement restrictor failure (p < 0.01) than the 78 patients who did not experience ipsilateral metachronous PJI during the study period. An analysis of the receiver operating characteristic curve showed a cutoff of 7 cm for the empty native bone distance (p < 0.01), with a sensitivity of 72% and a specificity of 75%. Conclusion The risk of ipsilateral metachronous PJI in patients with multiple joint arthroplasties is associated with shorter stature and stem-to-stem distance. Appropriate position of the cement restrictor and native bone distance are important in reducing the risk of ipsilateral metachronous PJI in these patients. Future studies might evaluate the risk of ipsilateral metachronous PJI owing to bone adjacency. Level of Evidence Level III, therapeutic study.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3