What is the Role of Stem Size and Offset in the Risk of Nonseptic Revision of the Exeter® 150-mm Stem? A Study From the Swedish Arthroplasty Register

Author:

Itayem Raed1,Rolfson Ola12,Mohaddes Maziar12,Kärrholm Johan12

Affiliation:

1. Department of Orthopaedics, Institute of Clinical Science, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden

2. The Swedish Arthroplasty Register, Gothenburg, Sweden

Abstract

Abstract Background The Exeter® stem is used worldwide, often in older patients, and it is the second most commonly used cemented stem design in Sweden. Previous studies have shown that for cemented stems with a composite beam, the smallest sizes result in an increased risk of revision for mechanical failure. However, little is known about whether the survivorship of the polished Exeter stem, which generally has been shown to be good, might be associated with design parameters such as stem dimensions or offset at extreme implant sizes. Question/purpose Are differences in (1) stem size or (2) offset of the standard Exeter V40 150-mm stem associated with differences in the risk of stem revision for aseptic loosening? Methods Between 2001 and 2020, 47,161 Exeter stems were reported to the Swedish Arthroplasty Register, with very high coverage and completeness documented during the period studied. In this cohort, we included patients with primary osteoarthritis who underwent surgery with a standard Exeter stem length of 150 mm and V40 cone with any type of cemented cups that had had at least 1000 reported insertions. This selection resulted in a study cohort representing 79% (37,619 of 47,161) of the total number of Exeter stems in the registry during that time. The primary study outcome was stem revision for aseptic indications such as loosening, periprosthetic fracture, dislocation, and implant fracture. A Cox regression was performed, with adjustment for age, gender, surgical approach, year of surgery, use of highly crosslinked polyethylene cups, and femoral head size and length dictated by the shape of the head trunnion. Adjusted hazard ratios are presented with 95% confidence intervals. Two separate analyses were performed. The first analysis excluded stems with the highest offsets (50 mm and 56 mm, which were not available for stem size 0). The second analysis excluded stem size 0 to include all offsets. Because stem survival was not proportional over time, we divided the analyses into two insertion periods, 0 to 8 years and beyond 8 years. Results Stem size 0 (compared to size 1) was associated with an increased risk of revision up to 8 years when all stem sizes were included (first analysis 0 to 8 years, HR 1.7 [95% CI 1.2 to 2.3]; p = 0.002). Forty-four percent (63 of 144) of revisions of size 0 stems were for periprosthetic fracture. There was no consistent association between stem size and risk of aseptic stem revision when size 0 was excluded in the second analysis beyond 8 years. The most common offset (44 mm) was associated with an increased risk of revision (compared with 37.5 mm) up to 8 years when all sizes were included (first analysis, HR 1.6 [95% CI 1.1 to 2.1]; p = 0.01). In the second analysis (beyond 8 years, all offsets included), offset of 44 mm was compared with offset of 37.5 mm; compared with the first period, this offset was associated with a reduced risk (HR 0.6 [95% CI 0.4 to 0.9]; p = 0.005). Conclusion We found overall high survival of the Exeter stem, with generally little or no influence of stem variations on the risk of aseptic revision. However, stem size 0 was associated with an increased risk of revision mainly for periprosthetic fractures. If the femoral anatomy offers a choice between sizes 0 and 1 in patients with poor bone quality who are at risk of periprosthetic fracture, our data speak in favor of choosing the larger stem if the surgeon believes it is safe to insert the larger size, or, if available, another stem design that has a documented lower risk of this complication. For patients with good cortical bone quality but very narrow canals, a cementless stem may also be a good alternative. Level of Evidence Level III, therapeutic study.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Surgery

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3