Use of Percutaneous Left Ventricular Assist Device Before Durable Device Implantation in Patients With Cardiac Cachexia: Case Series

Author:

Salas De Armas Ismael A.1,Bergeron Amanda2,Akkanti Bindu3,Akay Mehmet H.1,Scovell Alison2,Patel Manish K.1,Patel Jayeshkumar1,Bhardwaj Anju1,Al Rameni Dina1,Marcano Juan1,Nascimbene Angelo1,Kar Biswajit1,Gregoric Igor D.1ORCID

Affiliation:

1. Department of Advanced Cardiopulmonary Therapies and Transplantation, The University of Texas Health Science Center at Houston, Houston, Texas

2. Memorial Hermann Hospital-Texas Medical Center, Houston, Texas

3. Divisions of Pulmonary, Critical Care, and Sleep, The University of Texas Health Science Center at Houston, Houston, Texas.

Abstract

Frailty and malnutrition in patients with heart failure are barriers to durable left ventricular assist device (D-LVAD) support and heart transplantation. Moreover, cachexia in patients with advanced heart failure carries a high mortality risk. There are no guidelines for these patients other than increased caloric intake and rehabilitation. Patients suffering from cardiac cachexia and heart failure may benefit from temporary, percutaneous assist device support to improve the underlying heart disease and reverse the catabolic state. We retrospectively reviewed patients from January 2017 to January 2022. All patients who received Impella support (5.0 or 5.5, Abiomed) before D-LVAD implantation were screened. Those who met the criteria for cardiac cachexia were included. Patient demographics, nutritional and biochemical markers, and survival data were collected. A total of 14 patients were included. The majority of patients were male (85.7%) with ischemic cardiomyopathy (64.3%). Caloric intake, physical strength, and ambulation improved. Prealbumin levels improved from a median of 13.7–18.0 mg/dl (p < 0.006) while on Impella 5.0 or 5.5 support. All patients survived to discharge and the 6 month follow-up. In conclusion, use of the Impella device improves cardiogenic shock symptoms and, consequently, may improve cachexia status prior to D-LVAD implantation.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Biomedical Engineering,General Medicine,Biomaterials,Bioengineering,Biophysics

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3