MarioHeart: Novel In-Vitro Flow Model for Testing Heart Valve Prostheses and Anticoagulant Therapies

Author:

Devos Maxime1,Liesdek Omayra C. D.23,Suyker Willem J. L.2,van Tuijl Sjoerd4,Schutgens Roger E. G.3,van de Vosse Frans N.1,de Heer Linda M.2,Rutten Marcel C. M.1

Affiliation:

1. Cardiovascular Biomechanics Group, Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, the Netherlands

2. Department of Cardiothoracic Surgery, University Medical Center Utrecht, Utrecht, the Netherlands

3. Van Creveldkliniek, Benign Hematology Center, University Medical Center Utrecht and University Utrecht, Utrecht, the Netherlands

4. LifeTec Group BV, Eindhoven, the Netherlands.

Abstract

Mechanical heart valve (MHV) prostheses present a risk of thromboembolic complications despite antithrombotic therapy. Further steps in the development of more hemocompatible MHVs and new anticoagulants are impeded due to the lack of adequate in-vitro models. With the development of a novel in-vitro model (MarioHeart), a pulsatile flow similar to the arterial circulation is emulated. The MarioHeart design owns unique features as 1) a single MHV within a torus with low surface/volume ratio, 2) a closed loop system, and 3) a dedicated external control system driving the oscillating rotational motion of the torus. For verification purposes, a blood analog fluid seeded with particles was used to assess fluid velocity and flow rate using a speckle tracking method on high-speed video recordings of the rotating model. The flow rate resembled the physiological flow rate in the aortic root, in both shape and amplitude. Additional in-vitro runs with porcine blood showed thrombi on the MHV associated with the suture ring, which is similar to the in-vivo situation. MarioHeart is a simple design which induces well-defined fluid dynamics resulting in physiologically nonturbulent flow without stasis of the blood. MarioHeart seems suitable for testing the thrombogenicity of MHVs and the potential of new anticoagulants.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Biomedical Engineering,General Medicine,Biomaterials,Bioengineering,Biophysics

Reference32 articles.

1. Guidelines on the management of valvular heart disease: The Task Force on the Management of Valvular Heart Disease of the European Society of Sardiology.;Vahanian;Eur Heart J,2007

2. Allograft aortic valve replacement: Long-term follow-up.;O’Brien;Ann Thorac Surg,1995

3. Prosthetic heart valves.;Vongpatanasin;N Engl J Med,1996

4. Outcomes 15 years after valve replacement with a mechanical versus a bioprosthetic valve: Final report of the Veterans Affairs randomized trial.;Hammermeister;J Am Coll Cardiol,2000

5. Twelve-year comparison of a Bjork-Shiley mechanical heart valve with porcine bioprostheses.;Bloomfield;N Engl J Med,1991