Right Ventricular Contractility and Pulmonary Arterial Coupling After Less Invasive Left Ventricular Assist Device Implantation

Author:

Adly George1ORCID,Mithoefer Oliver1,Elliott Epps John1,Hajj Jennifer M.1,Hambright Elizabeth1,Jackson Gregory R.1,Inampudi Chakradhari1,Atkins Jessica1,Griffin Jan M.1,Carnicelli Anthony P.1,Witer Lucas J.2,Kilic Arman2,Houston Brian A.1,Vanderpool Rebecca R.3,Tedford Ryan J.1ORCID

Affiliation:

1. Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, South Carolina

2. Division of Cardiothoracic Surgery, Medical University of South Carolina, Charleston, South Carolina

3. Division of Cardiovascular Medicine, The Ohio State University, Columbus, Ohio.

Abstract

Right ventricular failure contributes significantly to morbidity and mortality after left ventricular assist device implantation. Recent data suggest a less invasive strategy (LIS) via thoracotomy may be associated with less right ventricular failure than conventional median sternotomy (CMS). However, the impact of these approaches on load-independent right ventricular (RV) contractility and RV-pulmonary arterial (RV-PA) coupling remains uncertain. We hypothesized that the LIS approach would be associated with preserved RV contractility and improved RV-PA coupling compared with CMS. We performed a retrospective study of patients who underwent durable, centrifugal left ventricular assist device implantation and had paired hemodynamic assessments before and after implantation. RV contractility (end-systolic elastance [Ees]), RV afterload (pulmonary effective arterial elastance [Ea]), and RV-PA coupling (Ees/Ea) were determined using digitized RV pressure waveforms. Forty-two CMS and 21 LIS patients were identified. Preimplant measures of Ees, Ea, and Ees/Ea were similar between groups. After implantation, Ees declined significantly in the CMS group (0.60–0.40, p = 0.008) but not in the LIS group (0.67–0.58, p = 0.28). Coupling (Ees/Ea) was unchanged in CMS group (0.54–0.59, p = 0.80) but improved significantly in the LIS group (0.58–0.71, p = 0.008). LIS implantation techniques may better preserve RV contractility and improve RV-PA coupling compared with CMS.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Biomedical Engineering,General Medicine,Biomaterials,Bioengineering,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3