Can high-sensitive troponin levels within the normal range predict positivity in treadmill test?

Author:

Yilmaz Mustafa1,Atici Adem2,Sonsöz Mehmet Rasih3,Çevik Erdem3,Orta Hüseyin3,Demirtakan Zeynep Gizem3,Barman Hasan Ali4,Bulat Zubeyir4,Karaayvaz Ekrem Bilal3,Mercanoğlu Fehmi3,Zorkun Cafer3

Affiliation:

1. Cardiology Department, Bağcilar Medipol Mega University Hospital

2. Cardiology Department, Istanbul Medeniyet University Faculty of Medicine, Goztepe Training and Research Hospital

3. Cardiology Department, Istanbul University Istanbul Faculty of Medicine

4. Cardiology Department, Faculty of Medicine, Istanbul University – Cerrahpasa, Institute of Cardiology, Istanbul, Turkey

Abstract

Background This study aimed to determine whether a high level of high-sensitivity troponin T (hsTnT) predicts a positive treadmill test in patients with suspected stable ischemic heart disease (SIHD). Methods In all, 366 patients with suspected SIHD were included in the study. We measured the serum hsTnT levels before the treadmill test. The treadmill test was performed according to the Bruce protocol. Results Of the 366 patients, 97 had positive treadmill tests. The hsTnT levels were significantly higher in the positive group than in the negative group. In the binary logistic regression analysis, hsTnT, pretest probability, metabolic equivalents (METs), target heart rate (THR) percentage, and Duke treadmill score (DTS) were independent predictors of a positive treadmill test [hsTnT odds ratio (OR): 2.178, P < 0.001; pretest probability OR: 1.036, P = 0.007; METs OR: 0.755, P = 0.008; THR OR: 0.773, P < 0.001; DTS OR: 2.661, P = 0.012]. In the receiver operating characteristic (ROC) curve analysis, the area under the curve (AUC) value of the model with the combined parameters of hsTnT, pretest probability, METs, THR, and DTS was statistically significant in predicting a positive treadmill test [combined model AUC: 0.945 (0.922–0.968), P < 0.001]. Conclusions In sum, high pretest hsTnT levels predicted a positive treadmill test in patients with suspected SIHD. Analysis of the hsTnT levels before the treadmill test can increase the sensitivity and specificity of the treadmill test. The methods for measuring hsTnT levels are cheap and easily accessible and can be used before the treadmill test in patients with suspected SIHD.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3