Development of saliva-based cardiac troponin I point-of-care test using alpha-amylase depletion: a feasibility study

Author:

Westreich Roi1,Tsaban Gal1,Neumann Yoav2,Abu Salman Amjad1,Braver Omri1,Braiman Dana1,Zamed Tali1,Neuhaus Zipora Feiga1,Deutsch Omer2,Palmon Aaron2,Maimon Nimrod1,Zahger Doron1,Abramowitz Yigal1

Affiliation:

1. Department of Cardiology, Soroka University Medical Center, Faculty of Health Sciences, Ben Gurion University of the Negev, Beer-Sheva

2. Department of D&R, Faculty of Dental Medicine, Hebrew University, Jerusalem, Israel

Abstract

Introduction: Cardiac troponin (cTn) is the biomarker of choice for detection of myocardial injury. There is a great need for simple point-of-care (POC) troponin testing among patients with chest pain, mainly in the prehospital setting. The purpose of this study was to evaluate the presence of cardiac troponin I (cTnI) in saliva of patients with myocardial injury using alpha-amylase depletion technique. Methods: Saliva samples were collected from 40 patients with myocardial injury who were tested positive for conventional high-sensitivity cardiac troponin T (cTnT) blood tests, and from 66 healthy volunteers. Saliva samples were treated for the removal of salivary alpha-amylase. Treated and untreated samples were tested with blood cTnI Rapid Diagnostic Test. Salivary cTnI levels were compared to blood cTnT levels. Results: Thirty-six of 40 patients with positive blood cTnT had positive salivary samples for cTnI following alpha-amylase depletion treatment (90.00% sensitivity). Moreover, three of the four negative saliva samples were obtained from patients with relatively low blood cTnT levels of 100 ng/L or less (96.88% sensitivity for 100 ng/L and above). The negative predictive value was 93.65% and rose up to 98.33% considering the 100 ng/L cutoff. Positive predictive values were 83.72% and 81.58%, respectively. Among 66 healthy volunteers and 7 samples yielded positive results (89.39% specificity). Conclusion: In this preliminary work, the presence of cTnI in saliva was demonstrated for the first time to be feasibly identified by a POC oriented assay. The specific salivary alpha-amylase depletion technique was shown to be crucial for the suggested assay.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Cardiology and Cardiovascular Medicine,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3