Improved Performance With the Micro-Hole Zone Intermittent Catheter

Author:

Landauro Malene HornbakORCID,Tentor Fabio,Pedersen Troels,Jacobsen Lotte,Bagi Per

Abstract

PURPOSE: To assess the performance of a new urinary intermittent catheter (IC) prototype designed with a micro-hole drainage zone compared to a conventional eyelet catheter (CEC) in terms of flow-stop, bladder emptying, and hematuria. DESIGN: Randomized controlled crossover studies. SUBJECT AND SETTING: The sample comprised 15 male healthy volunteers (HV) and 15 IC users, along with 15 female HV and 15 IC users. The age range was lower for HV participants than for IC users (range: 20-57 years for HV vs 21-82 years for IC users). The study setting was the Department of Urology, located in Rigshospitalet, Copenhagen. METHODS: Number of flow-stop incidents, residual urine volume at first flow-stop (RV1), and dipstick hematuria were measured during and after catheterization by a health care professional (HV) and by self-catheterisation (IC-users). Results from the 3 studies were combined for HV and IC users on RV1 and number of flow-stop incidents but separated on sex. For incidents of hematuria, an effect of underlying condition was assumed, and a combined analysis on sex was performed, separating HV and IC users. RESULTS: When compared to the micro-hole drainage zone design, catheterizations with CEC resulted in a significantly higher mean RV1 (mean difference: 49 mL in males and 32 mL in females, both P < .001) and average number of flow-stop incidents (8 and 21 times more frequent for males and females, respectively, both P < .001). The likelihood for hematuria was 5.84 higher with CEC than with micro-hole drainage hole design, P = .053, during normal micturition in HV postcatheterization. No serious adverse events were reported. CONCLUSION: The micro-hole drainage zone catheter provides IC users fewer premature flow-stops. This design feature reduces modifiable urinary tract infection risk factors, such as residual urine and micro-trauma; additional research is needed to determine its effects on bladder health.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Advanced and Specialized Nursing,Medical–Surgical Nursing

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3