Prolonging the zone 1 aortic occlusion time to 4 hours using a partial resuscitative endovascular balloon in a swine model

Author:

Ho Jessie W.,Jin Guang,Nguyen Jessica,Keeney-Bonthrone Toby P.,Diaz-Perez Dariel A.,Dawood Zaiba Shafik,Kemp Michael T.,Alam Jenna S.,Gauger Megan A.,Shaikh Aleezeh,Chtraklin Kiril,Liu Baoling,Alam Hasan B.

Abstract

BACKGROUND The clinical usage of the resuscitative endovascular balloon occlusion of the aorta (REBOA) is limited by distal ischemia resulting from complete aortic occlusion. We hypothesized that animals would physiologically tolerate the prolonged partial occlusion using the novel partially occluding REBOA (pREBOA) with survivable downstream injuries. METHODS This study used the pREBOA-PRO catheter in a previously established swine model. Female Yorkshire swine (n = 10) underwent a volume-controlled hemorrhage (40% estimated blood). After 1 hour of shock (mean arterial pressure, 28–32 mm Hg), animals were randomized to partial occlusion for either 2 hours or 4 hours. The pREBOA was inflated in zone 1 to achieve partial occlusion defined as a distal systolic blood pressure (SBP) of 20 ± 2 mm Hg. The balloon was deflated at the end of the occlusion period, and animals were resuscitated for 2 hours. Tissues were examined for gross and histologic injury. The primary endpoint was histologic organ injury, and secondary end points were hemodynamic variables and degree of distal organ ischemia. RESULTS All animals survived to the endpoint. Both groups had similar proximal and distal SBP at baseline, with a divergence of pressures ranging from 55 mm Hg to 90 mm Hg on inflation. The lactate levels increased throughout the occlusion and decreased approximately 40% during the observation period. More animals required norepinephrine and fluid in the 4-hour group compared with the 2-hour group. There was no gross small bowel ischemia noted in the 2-hour animals. The 4-hour group had surgically resectable patchy short segment ischemia. Neither group showed nonsurvivable organ ischemia on pathology or laboratory values. CONCLUSION This is the first study showing that the zone 1 aorta can be occluded for over 4 hours using a new pREBOA device without need for balloon titration. In conclusion, simple changes in balloon design offer reliable partial aortic occlusion, with potentially survivable and surgically manageable downstream injuries.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Critical Care and Intensive Care Medicine,Surgery

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3