Estimating Changes in Glomerular Filtration Rate With Fluorescein Isothiocyanate-Sinistrin During Renal Replacement Therapy

Author:

Chan Goldia1,Pino Christopher J.23ORCID,Johnston Kimberly A.23,Humes H. David23

Affiliation:

1. Department of Veterinary Medicine, University of Michigan, Ann Arbor, Michigan

2. Innovative BioTherapies, Inc., Ann Arbor, Michigan

3. Department of Internal Medicine-Nephrology, University of Michigan, Ann Arbor, Michigan.

Abstract

Excreted exclusively by the kidneys, fluorescein isothiocyanate (FITC)-sinistrin can be used to measure glomerular filtration rate (GFR) and is detectable transdermally. Determination of changes in native kidney GFR (NK-GFR) in patients with acute kidney injury, particularly during continuous renal replacement therapy, improves clinical decision-making capability. To test feasibility of measuring changes in NK-GFR during CRRT with FITC-sinistrin, in vitro circuits (n = 2) were utilized to simultaneously clear FITC-sinistrin by removal of ultrafiltrate at varying rates, simulating kidney function, and by dialysis at a constant rate. Clearance calculated by fluorescence-measuring devices on the circuit showed good agreement with clearance calculated from assay of fluid samples (R 2 = 0.949). In vivo feasibility was studied by dialyzing anesthetized pigs (n = 3) and measuring FITC-sinistrin clearance during progression from normal, to unilaterally, then bilaterally nephrectomized. FITC-sinistrin clearance was reduced in vitro, when ultrafiltrate was decreased or with successive nephrectomies in vivo. Transdermal readers showed 100% sensitivity in detecting a decrease in NK-GFR in pigs with a bias of 6.5 ± 13.4% between transdermal-derived GFR (tGFR) and plasma-measured methods determining proportional changes in clearance. Clearance of FITC-sinistrin by dialysis remained consistent. In patients receiving a constant dialysis prescription, transdermal measurement of FITC-sinistrin can detect relative changes in NK-GFR.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Biomedical Engineering,General Medicine,Biomaterials,Bioengineering,Biophysics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3