Effect of transtibial prosthesis weight on the contralateral knee joint in relation to the risk of osteoarthritis

Author:

Krawczyk Petr12ORCID,Uchytil Jaroslav3ORCID,Rygelova Marketa3ORCID,Buzga Marek3ORCID,Zemkova Daniela45ORCID,Sykora Ales2,Marik Ivo56ORCID

Affiliation:

1. Department of Anatomy and Biomechanics, Faculty of Physical Education and Sport, Charles University, Prague, Czech Republic

2. PROTEOR CZ LLC, Ostrava, Czech Republic

3. Department of Human Movement Studies, Human Motion Diagnostic Centre, University of Ostrava, Ostrava, Czech Republic

4. Department of Paediatrics, Charles University Hospital Motol, Prague, Czech Republic

5. Centre for Defects of Locomotor Apparatus LLC, Prague, Czech Republic

6. Faculty of Medical Studies, West Bohemia University, Pilsen, Czech Republic

Abstract

Background: Individuals with transtibial amputation place more load on the contralateral lower extremity. A higher adduction moment at the knee joint has been shown to have an effect on the risk of osteoarthritis. Objective: The aim of this study was to investigate the effect of weight-bearing of lower-limb prosthesis on the biomechanical parameters associated with the risk of contralateral knee osteoarthritis. Study design: Cross-sectional. Methods: The experimental group of 14 subjects with unilateral transtibial amputation (13 males). The mean age was 52.7 ± 14.2 years, height 175.6 ± 6.3 cm, weight 82.3 ± 12.5 kg, and duration of prosthesis use 16.5 ± 9.1 years. The control group consisted of 14 healthy subjects with identical anthropometric parameters. Dual emission X-ray absorptiometry was used to determine the weight of the amputated limb. For gait analysis, 10 Qualisys infrared cameras and a motion sensing system on 3 Kistler force platforms were used. Gait was analyzed with the original, lighter, commonly used prosthesis, as well as the prosthesis loaded to the original limb weight. Results: The gait cycle and kinetic parameters of the amputated and healthy limbs were more similar to those of the control group when using the weighted prosthesis. Conclusions: We recommend further research to more accurately specify the weight of the lower-limb prosthesis with respect to the prosthesis design and duration of use of the heavier prosthesis during the day.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Rehabilitation,Health Professions (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3