Development of a prosthetic fit and alignment assessment (ProFit) in persons with post-traumatic transtibial amputation

Author:

Abstract

Background: There are no standards for reliably measuring the quality of prosthetic fit and alignment which is important for evaluation and improvement of clinical care for patients with transtibial amputation. Objectives: The purpose of this study was to develop an instrument to quantitatively assess prosthetic fit and alignment in patients with transtibial amputation. Study Design: Prospective cohort study. Methods: The fit and alignment assessment (ProFit) included 39 items for assessments of skin quality, stance and gait, and radiographic characteristics that could be feasibly captured in clinic using photographs, video, and radiographs. Data were collected on adults aged 18–60 years treated with transtibial amputation and followed up for 18 months at 1 of 27 US hospitals. One hundred thirteen assessments were conducted by 6 prosthetists using an online platform. Items demonstrating reliability and face validity were included in the ProFit score for subsequent validation testing. Validation measures included 18-month patient-reported function (Short Musculoskeletal Function Assessment ), tests of physical performance, patient-reported pain (Brief Pain Inventory ), satisfaction with prosthesis (Orthotics Prosthetics Users Survey), prosthesis use, and walking activity. Results: The ProFit score included 10 of 39 items that demonstrated high inter-rater reliability and face validity. A higher ProFit score correlated with worse function on all domains of the Short Musculoskeletal Function Assessment except arm and hand and with worse performance on the 4-Square Step Test, Shuttle Run, and Illinois Agility Test. ProFit scores did not correlate with the Brief Pain Inventory, Orthotics Prosthetics Users Survey, prosthesis use, or walking activity. Conclusions: The ProFit score can be used by researchers and clinicians to measure the quality of socket fit and prosthetic alignment. Future prospective validation is necessary to verify the promising results observed in ProFit development and establish clinical utility.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Rehabilitation,Health Professions (miscellaneous)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3