Socket-residuum coupling integrity affects perception of external stimuli: Effects of altering the transtibial interface using vacuum-assisted suspension

Author:

Kent Jenny A.12ORCID,Carnahan Kristin J.2,Major Matthew J.234ORCID

Affiliation:

1. Department of Physical Therapy, University of Nevada Las Vegas, Las Vegas, NV

2. Department of Physical Medicine and Rehabilitation, Northwestern University, Chicago, IL

3. Department of Biomedical Engineering, Northwestern University, Evanston, IL

4. Jesse Brown VA Medical Center, Chicago, IL

Abstract

Background: Relative movement between the socket and residual limb can impair function in prosthesis users. It is plausible that, in addition to its mechanical effect, the integrity of the socket-residuum interface influences the ability of an individual to sense tactile cues through the prosthesis. Vacuum-assisted suspension (VAS) has been shown to reduce relative movement at this interface, providing a means to test this premise. The purpose of this pilot study was to assess the effects of altering socket-residuum interface integrity through the VAS pressure level on the thresholds of perception of an externally applied vibration stimulus. Methods: Seven unilateral transtibial prosthesis users participated. Socket-residual limb integrity was altered using the VAS subatmospheric (vacuum) pressure level. Vibration perception tests were conducted at low, mid, and high vacuum levels, targeting 0, 8, and 19 in Hg respectively, and performed in partially loaded and fully loaded conditions. Vibration intensity was increased using a dial until participants delivered a verbal signal indicating it was perceptible, and the nominal intensity was recorded. Results: Intensity thresholds decreased (ie, sensitivity increased) from low to high vacuum settings when fully loaded (P = 0.008). Differences when partially loaded were nonsignificant and variable across participants. Conclusion: This study provides preliminary evidence that altering the integrity between the socket and residual limb by modifying the vacuum level affects sensation related to the external environment experienced through the prosthesis, although translation of these findings to real-world stimuli remains to be tested.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Rehabilitation,Health Professions (miscellaneous)

Reference27 articles.

1. Socket considerations for the patient with a transtibial amputation;Fergason;Clin Orthop Relat Res,1999

2. Pistoning assessment in lower limb prosthetic sockets;Eshraghi;Prosthet Orthot Int,2012

3. Interface pressures during ambulation using suction and vacuum-assisted prosthetic sockets;Beil;J Rehabil Res Dev,2002

4. A comparison of trans-tibial amputee suction and vacuum socket conditions;Board;Prosthet Orthot Int,2001

5. Axial bone-socket displacement for persons with a traumatic transtibial amputation: The effect of elevated vacuum suspension at progressive body-weight loads;Darter;Prosthet Orthot Int,2016

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3