The Dose Spiking Technique for Measuring Low Doses in Deciduous Teeth Enamel Using EPR Spectroscopy for Retrospective and Accident Dosimetry

Author:

Ghimire Lekhnath,Waller Edward1

Affiliation:

1. Faculty of Energy Systems and Nuclear Science, Ontario Tech University, Oshawa, ON, L1G 0C5, Canada.

Abstract

Abstract Dose estimation by electron paramagnetic resonance (EPR) has been accomplished using the standard EPR dosimetry technique (ISO protocol 13304-1 for EPR retrospective dosimetry). However, different studies showed that these techniques have high measurement errors in measuring the low doses (10–100 mGy) in enamel. This work proposes a new method to make a dosimetric signal visible and measurable at low doses. The sample was purified using both chemical and mechanical processes. The pure sample mass and position and the EPR acquisition parameters were optimized to enhance the spectrometer's sensitivity for the quantitative low dose measurements. At the same time to reduce errors from the sample and spectrum anisotropy, the total doses (low plus spike) and the spike dose (4 Gy) were measured by rotating 0 to 360 degrees (i.e., 40 degrees at a time) relative to constant magnetic field direction using a goniometer. Subsequently, the spectra were averaged after their g-factor normalization. However, at low doses (<30 mGy), the radiation induced signal (RIS) was obscured by the background signal (BGS). So, the dose spiking technique was used as an alternative method. Ten low-dose deciduous molar tooth enamel (10–100 mGy) samples were spiked to the higher doses by delivering 4 Gy and measured using the X-band continuous wave (CW) EPR (Bruker EMXmicro) spectrometer. The total dose EPR signal was distinctly visible, and the peak-to-peak (P2P) amplitude height was measured. Then, the total dose was subtracted with the spike, often called a reference sample, to determine the initial low doses. The measurement errors using this method were lower than the previous methods. These results demonstrated that this method could be promising for solving low dose measurement problems in EPR dosimetry with deciduous and permanent tooth enamel.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Health, Toxicology and Mutagenesis,Radiology, Nuclear Medicine and imaging,Epidemiology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3