Comparison between cone-beam breast-CT and full-field digital mammography for microcalcification detection depending on breast density

Author:

Wienbeck Susanne12,Andrijevska Viktorija3,Kück Fabian4,Perske Christina5,Unterberg-Buchwald Christina16,Fischer Uwe7,Lotz Joachim1,Kunze Meike18

Affiliation:

1. University Medical Center Goettingen, Institute of Diagnostic and Interventional Radiology, Goettingen, Germany

2. Radiology Practice Schwarzer Baer MVZ, Hannover, Germany

3. University Medical Center Goettingen, Goettingen, Germany

4. Core Facility Medical Biometry and Statistical Bioinformatics, University of Goettingen, Goettingen, Germany

5. University Medical Center Goettingen, Institute for Pathology, Goettingen, Germany

6. University Medical Center Goettingen, Department of Cardiology and Pneumology, Goettingen, Germany

7. Diagnostic Breast Center, Goettingen, Germany

8. Städtisches Klinikum Karlsruhe, Institute for Diagnostic and Interventional Radiology, Karlsruhe, Germany.

Abstract

The purpose of this study was to evaluate the impact of breast density on the diagnostic performance of cone-beam breast-CT (CBBCT) in comparison to full-field digital mammography (FFDM) for the detection of microcalcifications. This retrospective IRB-approved study was conducted between December 2015 and March 2017 and enrolled 171 women with Breast Imaging Reporting and Data System category 4 or 5 lesions on FFDM and additional CBBCT; 56 of which were ineligible. The inclusion was restricted to 83 women (90 breasts, 90 lesions) with microcalcifications. All lesions underwent histology or were monitored by FFDM and a clinical examination at least 2 years after enrollment. Two breast radiologists independently read each data set twice. Sensitivity, specificity and area under the curve were compared between the modalities. Thirty-two breasts (35.5%) were grouped as non-dense breasts (American College of Radiology types a/b) and 58 breasts (64.5%) as dense breasts (American College of Radiology types c/d). Histopathological assessment was performed in 61 of 90 breast lesions (32 malignant, 1 high-risk and 28 benign). Area under the curve was larger for FFDM than for CBBCT (P = .085). The sensitivity was significantly higher for FFDM compared to CBBCT (P = .009). The specificity showed no significant differences comparing FFDM (both readers: 0.62) versus CBBCT (reader 1: 0.76, reader 2: 0.60; P = .192). Inter-observer-reliability on BI-RADS readings was almost perfect for FFDM and moderate for CBBCT (κ = 0.84, κ = 0.54, respectively). Intra-observer agreement was substantial to almost perfect for both methods and readers. Compared with FFDM, CBBCT demonstrated non-comparable results for microcalcification detection in dense and non-dense breasts.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Reference36 articles.

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3