ECG-gated MR angiography at 3T for follow-up after surgery involving the ascending aorta

Author:

Busse Anke12,Neßelmann Catharina3,Streckenbach Felix1,Beller Ebba1,Klemenz Ann-Christin1,Dohmen Pascal34,Öner Alper5,Weber Marc-André1,Meinel Felix G.1ORCID

Affiliation:

1. Institute of Diagnostic and Interventional Radiology, Pediatric Radiology and Neuroradiology, University Medical Center, Rostock, Germany

2. Radiology Practice, Medical Care Center, Parchim, Germany

3. Department of Cardiac Surgery, University Medical Center, Rostock, Germany

4. Department of Cardiothoracic Surgery, Faculty of Health Science, University of the Free State, Bloemfontein, South Africa

5. Department of Internal Medicine, Division of Cardiology, University Medical Center, Rostock, Germany.

Abstract

We aimed to evaluate electrocardiogram (ECG)-gated MR angiography (MRA) in the follow-up after surgery involving the ascending aorta regarding technical feasibility, image quality, spectrum of findings, and their implications for clinical management. We retrospectively analyzed a cohort of 19 patients (median age 59 years, range 38–79 years), who underwent MRA for follow-up imaging after surgery involving the ascending aorta. Our magnetic resonance imaging protocol consisted of a time-resolved, non-ECG-gated MRA and an ECG-gated MRA performed at 3T. Median examination duration was 25 minutes (range 11–41 minutes). All examinations were assessed by 2 readers in consensus for image quality on a 5-point scale ranging from 1 (non-diagnostic) to 5 (excellent). MRA examinations and patient charts were analyzed for diagnostic findings and their consequences for further management. Subjective image quality was rated as “sufficient” (score 3.1 ± 1.1) for the aortic root and as “good” to “excellent” for the ascending aorta (score 4.5 ± 0.7), aortic arch (4.5 ± 0.7), supra-aortic branches (4.5 ± 0.6) and descending aorta (4.6 ± 0.7). Abnormal findings were seen in 6 patients (32%) including progressive diameter of remaining aneurysm or dissection (3 patients, 16%) and suture aneurysms (3 patients, 16%). In all 6 of these patients, abnormal findings at MRA had consequences for clinical management. ECG-gated MR angiography at 3T yields good image quality for post-operative surveillance after aortic surgery involving the ascending aorta. This technique may serve as an alternative to computed tomography particularly in younger patients with repeated follow-up.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3