Affiliation:
1. Division of Vascular and Endovascular Surgery, Department of Surgery, Kyungpook National University Hospital, Kyungpook National University School of Medicine, Daegu, South Korea.
Abstract
Introduction:
Current bifurcated aortic endografts are unsuitable for patients with a narrow distal aorta except AFX2, which is unavailable in South Korea. An iliac branch device (IBD) was introduced to exclude iliac aneurysms while preserving the pelvic circulation. With advancements in endovascular techniques, various attempts for outside instructions for use have been reported to be practicable in certain patients.
Patient concerns:
A 58-year-old man was referred to our emergency room with an incidentally found left common iliac artery aneurysm (CIAA) in a general checkup.
Diagnoses:
Computed tomography angiogram showed a narrow distal aorta that tapered from 20 mm just below the renal artery to 13 mm at aortic bifurcation and a left isolated CIAA with a maximal diameter of 40 mm and 70 mm in length.
Interventions:
After left hypogastric artery embolization, the Cook IBD was placed at the aortic bifurcation, and the Bard Covera Plus stent-graft was deployed from the IBD cuff to the left external iliac artery. Then, a reversed Medtronic Endurant iliac limb was implanted into the infrarenal aorta down to the proximal IBD.
Outcomes:
The stent grafts were patent without endoleak at the 6-month follow-up.
Lessons:
In selected patients with an isolated CIAA with a narrow distal aorta, IBD can be used as a main body at the aortic bifurcation for successful aneurysm exclusion. However, considering the application of outside instructions for use, special attention and careful planning must be taken before the procedure.