A novel method of assessment of BMD using CBCT for implant placement: A retrospective study

Author:

AlQahtani Saad Mohammed1ORCID

Affiliation:

1. Division of Periodontics, Department of Periodontics and Community Dental Sciences (PCS), College of Dentistry, King Khalid University, Abha, Kingdom of Saudi Arabia.

Abstract

Nowadays, dental implant evolves as an alternative treatment modality for oral rehabilitation. The success of dental implants is largely dependent on bone density; Cone-beam computed tomography (CBCT) is a well-known modus operandi for the volumetric measurement of bone mineral density (BMD), which measures Grayscale values on 3-D images. This study was conducted with the aim to analyze bone density with CBCT and also test its reliability and reproducibility using Galileos Sirona CBCT Viewer Software and Philips digital imaging and communications in medicine (DICOM) Viewer. A total of 75, CBCT images were obtained from the Department of Oral Radiology, retrospectively, and, BMD in Hounsfield units (HUs) was evaluated in a standardized implant area superimposed on the images. Bone density was also calculated by 2 different independent observers. The estimation of sample size was achieved to attain a power of 90% with 0.5 alpha error and 0.2 effect size as per a previous study. Statistical analysis was performed by statistical package for the social sciences version 22.0; data were presented as mean and standard deviation and Kappa correlation test was applied to check the reproducibility of values. The mean and standard deviation of grayscale values and HUs attained from the interdental area of front teeth were 1837 (288.76) and 270 (125.4), respectively, with a conversion factor of 6.8. Whereas the mean and standard deviation of grayscale values and HUs acquired from posterior interdental spaces were 2880 (489.99) and 640 (204.6), respectively, with a conversion factor of 4.5. To verify the reproducibility Kappa correlation test was applied, which showed correlation values of 0.68 and 0.79. The conversion or exchange factors for grayscale values to HUs determined at the frontal, posterior interdental space area and from the highly radio-opaque area were exceedingly reproducible and consistent. Hence, CBCT can be used as one of the valuable techniques in the estimation of bone density.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Reference36 articles.

1. Is there a lower threshold value of bone density for early loading protocols of dental implants?;Turkyilmaz;J Oral Rehabil,2008

2. Effects of immediate loading with threaded hydroxyapatite-coated root-form implants on single premolar replacements: a preliminary report.;Proussaefs;Int J Oral Maxillofac Implants,2002

3. Biological and biomechanical evaluation of bone remodelling and implant stability after using an osteotome technique.;Buchter;Clin Oral Implants Res,2005

4. Optimal implant stabilization in low density bone.;Martinez;Clin Oral Implants Res,2001

5. Conebeam CT of the head and neck, part 1: physical principles.;Miracle;AJNR Am J Neuroradiol,2009

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3