Corneal biomechanics after small incision lenticule extraction and femtosecond laser in situ keratomileusis: A systematic review and meta-analysis

Author:

Chen Songbai1,Ma Hongjie2,Zhao Congling1ORCID

Affiliation:

1. Aier Huangpi Eye Hospital, Wuhan, Hubei Province, China

2. Zhengzhou Aier Eye Hospital, Zhengzhou, Henan Province, China.

Abstract

Background: Small incision lenticule extraction (SMILE) and femtosecond laser in situ keratomileusis (FS-LASIK) have been extensively studied as the main surgical methods for corneal refractive surgery. However, there is no consensus on whether SMILE is superior to FS-LASIK in corneal biomechanics. Therefore, this systematic review and meta-analysis used the results of ocular response analyzer and corvis ST to explore whether SMILE is superior to FS-LASIK in corneal biomechanics. Methods: The literature was searched in PubMed, EMBASE, and Controlled Trials Register databases. The Cochrane Collaboration’s “risk of bias” tool was used to evaluate the quality of the included randomized clinical trials, and the Newcastle-Ottawa Scale was used to evaluate the included non-randomized controlled trials. The results were analyzed using Revman 5.3. Results: Sixteen studies (3 randomized clinical trials and 13 non-randomized controlled trials) were included in this meta-analysis. There was no statistical difference in corneal biomechanics between SMILE and FS-LASIK in corneal hysteresis [mean difference (MD), 0.20; 95% confidence interval (CI): −0.09, 0.49; P = .18] and corneal resistant factor (MD, 0.31; 95% CI: −0.09, 0.71; P = .13), A1 time (MD, −0.02; 95% CI: −0.11, 0.07; P = .66), A1 length (MD, 0.01; 95% CI: −0.01, 0.03; P = .42), A1 velocity (MD, 0.00; 95% CI: −0.01, 0.01; P = .85), A2 velocity (MD, −0.01; 95% CI: −0.11, 0.09; P = .86), HC time (MD, 0.12; 95% CI: −0.13, 0.38; P = .35), The stiffness parameter at first applanation (MD, −7.91; 95% CI: −17.96, 2.14; P = .12), The ratio between the deformation amplitude 2 mm away from apex and the apical deformation (MD, 0.01; 95% CI: −0.26, 0.27; P = .96). Conclusion: A comprehensive assessment of the parameters of ocular response analyzer and corvis ST showed that SMILE is not superior to LASIK in corneal biomechanics 3 months post-surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3