Comparison of pipeline classic and flex embolization devices in endovascular performance for intracranial aneurysms

Author:

Li Li1,Gao Bu-Lang1ORCID,Wu Qiao-Wei1,Li Tian-Xiao1,Shao Qiu-Ji1,Chang Kai-Tao1

Affiliation:

1. Henan Provincial People’s Hospital, Zhengzhou University, Zhengzhou, Henan Province, China.

Abstract

To investigate the endovascular performance of the Pipeline Classic embolization device (PED Classic) and PED Flex device (PED Flex) in the treatment of intracranial aneurysms. Fifty-three patients with intracranial aneurysms treated with the PED Classic were retrospectively enrolled into the PED Classic group, and 118 patients with intracranial aneurysms treated with the PED Flex were enrolled into the PED Flex group. The Procedure time, contrast dosage, fluoroscopy time, and perioperative complications were analyzed. The success rate of the stenting procedure was 100% in both groups. In the PED Classic group, 58 PED Classic devices were implanted, and 26 aneurysms underwent coil embolization. In the PED Flex group, 126 PED Flex devices were implanted, and 35 aneurysms underwent concomitant coil embolization. The procedure time was significantly (P < .001) greater in the PED Classic (159.0 ± 42.0 minutes) than in the PED Flex (121.9 ± 4.0 minutes) group. The dosage of contrast agent (156.4 ± 39.4 vs 110.1 ± 38.5 mL) and the total fluoroscopic time (34.7 ± 5.7 minutes vs 22.8 ± 7.6 minutes) were significantly (P < .001) greater in the PED Classic than in the PED Flex group. Peri-procedural complications occurred in 5 (9.4%) patients in the PED Classic group and in 3 (2.5%) patients in the Flex group, without a statistically significant (P = .11) difference. The performance of the PED Flex device may be safer and easier than that of the PED Classic device in the treatment of intracranial aneurysms despite some serious complications which remain to be prevented.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Reference16 articles.

1. Comparative analysis of unruptured cerebral aneurysm treatment outcomes and complications with the classic versus flex pipeline embolization devices and phenom versus marksman microcatheter delivery system: the role of microcatheter choice on complication rate.;Harland;J Vasc Interv Neurol,2020

2. Pipeline embolization device for intracranial aneurysms in a large Chinese cohort: complication risk factor analysis.;Kang;Neurotherapeutics,2021

3. Pipeline Flex Embolization Device (PED Flex) for the treatment of intracranial aneurysms: periprocedural outcomes and first-year angiographic results.;Oguz;Turk J Med Sci,2019

4. Safety and effectiveness of the pipeline flex embolization device with shield technology for the treatment of intracranial aneurysms: midterm results from a multicenter study.;Trivelato;Neurosurgery,2020

5. Pipeline for uncoilable or failed aneurysms: results from a multicenter clinical trial.;Becske;Radiology,2013

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献