Evaluation of brachial plexus stiffness in different arm and head positions by sonoelastography

Author:

Karakaya Muhammet Ahmet1ORCID,Darcin Kamil1,Ince Ilker2,Yenigun Yilmaz1,Kasali Kamber3,Dostbil Aysenur4

Affiliation:

1. Department of Anesthesiology and Reanimation, Koc University Hospital, Istanbul, Turkey

2. Department of Anesthesiology and Perioperative Medicine, Penn State University, Milton S Hershey Medical Center, Pennsylvania, USA

3. Department of Biostatistics, Faculty of Medicine, Ataturk University, Erzurum, Turkey

4. Department of Anesthesiology and Reanimation, Ataturk University Hospital, Erzurum, Turkey.

Abstract

Intraoperative positioning-related nerve injuries, particularly those affecting the brachial plexus, are concerning complications believed to arise from stretching and/or compression of peripheral nerves. Although sonoelastography, a new ultrasound technology, is emerging as a valuable tool in the musculoskeletal system, its utility in evaluating peripheral nerves remains unclear. This study aimed to utilize sonoelastography to assess the brachial plexus during surgery, specifically investigating changes in its stiffness values in relation to different head and arm positions. In this prospective cohort study, bilateral brachial plexuses of 8 volunteers in 3 different positions were enrolled. Using a high-frequency linear probe, the stiffness of the brachial plexus was quantitatively measured in kilopascals (kPa) under 3 different positions: neutral, head rotated, and head rotated with arm hyperabducted. Intra-class agreement was evaluated. The stiffness of the brachial plexus was 7.39 kPa in the neutral position (NP), 10.28 kPa with head rotation, and 17.24 kPa when the head was turned, and the ipsilateral arm was hyperabducted. Significant increases were observed in stiffness values when the head was turned, whether ipsilaterally or contralaterally, and during hyperabduction of the arm while the head was turned (for all P < .001). Strong intra-class correlations were found for the measurements of stiffness values (ICC = 0.988–0.989; P < .001; Cronbach Alpha = 0.987–0.989). Sonoelastography revealed significant increases in the stiffness of the brachial plexus with various head rotations and arm positions compared to the neutral state. These findings suggest that sonoelastography could potentially serve as a valuable tool for assessing the risk of brachial plexus injury during surgery and for guiding optimal patient positioning. Further research with larger sample sizes is needed to establish definitive clinical applications.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3