Effects of blue-light-filtering intraocular lenses on contrast sensitivity in patients with glaucoma

Author:

Kitnarong Naris1ORCID,Udomwech Lunla2,Chongthurakit Nisarate1,Phongsuphan Theerajate1,Petchyim Sakaorat1

Affiliation:

1. Department of Ophthalmology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok Noi, Thailand

2. Department of Clinical Science, Walailak University, Nakhon Si Thammarat, Thailand.

Abstract

To compare the effects of blue-light-filtering intraocular lenses (BF-IOLs) and conventional ultraviolet-blocking intraocular lenses (UVB-IOLs) on contrast sensitivity in patients with concurrent cataracts and glaucoma. This prospective randomized comparative interventional study enrolled glaucomatous patients with concurrent cataracts scheduled for cataract surgery with IOL implantation at Siriraj Hospital, Bangkok, Thailand, between October 2016 and March 2018. The patients were randomly assigned to receive BF-IOLs or UVB-IOLs. A functional vision analyzer measured contrast sensitivity at spatial frequencies of 1.5, 3.0, 6.0, 12.0, and 18.0 cycles per degree (CPD). The contrast sensitivity values of the 2 patient groups were compared at 2 months postoperatively. The study enrolled 42 eyes (21 with primary angle-closure glaucoma and 21 with primary open-angle glaucoma) of 32 patients. Twenty eyes received BF-IOLs, and 22 received UVB-IOLs. Postoperative logarithmic contrast sensitivity (log contrast sensitivity) significantly improved at each spatial frequency in both groups, except for 1.5 CPD. The median postoperative log contrast sensitivity values for the spatial frequencies of 1.5, 3.0, 6.0, 12.0, and 18.0 CPD for the BF-IOL group were 1.6, 1.9, 1.8, 1.4, and 0.6, respectively, compared to 1.4, 1.8, 1.7, 1.2, and 0.8 for the UVB-IOL group. However, the 2 groups had no significant differences in log contrast sensitivity values at each spatial frequency (P = .20, .37, .30, .28, and .68, respectively). Cataract surgery with IOL implantation improved contrast sensitivity in glaucomatous patients. The BF-IOLs and UVB-IOLs showed no statistically significant difference in the postoperative contrast sensitivity achieved at each spatial frequency.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3