Radiographical presentations of inadvertent subdural placement of an epidural catheter for successful labor analgesia: A case report

Author:

Chen Wei-An1,Wu Ming-Cheng1,Lam Chen-Fuh12ORCID,Ou Chang-Hsien3

Affiliation:

1. Department of Anesthesiology, E-Da Hospital and I-Shou University, Kaohsiung, Taiwan

2. Department of Anesthesiology, Dalian Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Chia-Yi, Taiwan

3. Department of Neuroradiology, E-Da Hospital and I-Shou University, Kaohsiung, Taiwan.

Abstract

Rationale: Lumbar epidural analgesia is the gold standard for labor pain control. However, misplacement of epidural catheters into the subdural space may inadvertently happen. Unrecognized subdural administration of local anesthetics could result in serious consequences, including high spinal and brainstem blocks. This case report describes a case where subdural epidural catheter placement was recognized early but labor pain was adequately managed by dosage titration of subdural analgesia. Patient concerns: This case report describes a 29-year-old primiparous pregnant woman who was admitted to our obstetric unit for labor induction at the gestational age of 38 weeks. An epidural catheter was inserted via the L2-3 intervertebral space using the standard loss of resistance to air technique. Diagnoses: The parturient experienced weakness in the lower extremities and numbness in the upper extremities within 15 minutes after administration of 5 mL of 2% v/v lidocaine as a loading dose and systolic blood pressure also dropped by 25%. Interventions: The dose regimen (a mixture of 0.1% ropivacaine and 4 μg/mL fentanyl) for patient-controlled analgesia was given with bolus doses of 0.1 mL per demand and lockout intervals of 20 minutes. The analgesic effects were adequately maintained below the T8 dermatome for more than 12 hours without hypotensive episodes or obvious signs of neurological deficits. Computed tomographic myelography was performed by instillation of a nonionic iodinated contrast medium via the epidural catheter on postpartum day 2 for imaging confirmation of catheter placement in the extradural space. Lessons: Early recognition that epidural catheters for neuraxial analgesia have been inserted into the subdural space is important for the prevention of high spinal blocks. Subdural analgesia could still be achieved by careful clinical assessment and titration of low analgesic doses. This report also presents important and clear serial computed tomographic images of catheter placement in the thoracic-lumbar subdural spaces and the extent of volume spread in the subdural space following administration of contrast medium.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Reference6 articles.

1. Variations in use of childbirth interventions in 13 high-income countries: a multinational cross-sectional study.;Seijmonsbergen-Schermers;PLoS Med,2020

2. Case report: subdural anesthesia in the obstetric patient.;Palacio-Garcíaa;Rev Colomb Anestesiol,2016

3. Subdural block and the anaesthetist.;Agarwal;Anaesth Intensive Care,2010

4. Incidence of subdural catheter placement during epidural procedure based on fluoroscopic imaging.;Sidash;Reg Anesth Pain Med,2021

5. Some immediate serious complications of obstetric epidural analgesia and anaesthesia: a prospective study of 145,550 epidurals.;Jenkins;Int J Obstet Anesth,2005

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3