Prospective observational study of 2 wearable strain sensors for measuring the respiratory rate

Author:

Sato Hiroki1ORCID,Nagano Tatsuya1ORCID,Izumi Shintaro2,Yamada Jun1,Hazama Daisuke1,Katsurada Naoko1,Yamamoto Masatsugu1,Tachihara Motoko1,Nishimura Yoshihiro3,Kobayashi Kazuyuki1

Affiliation:

1. Division of Respiratory Medicine, Department of Internal Medicine, Kobe University Graduate School of Medicine, Hyogo, Japan

2. Graduate School of System Informatics, Kobe University, Hyogo, Japan

3. Department of Respiratory Medicine, Kitaharima Medical Center, Hyogo, Japan.

Abstract

The respiratory rate is an important factor for assessing patient status and detecting changes in the severity of illness. Real-time determination of the respiratory rate will enable early responses to changes in the patient condition. Several methods of wearable devices have enabled remote respiratory rate monitoring. However, gaps persist in large-scale validation, patient-specific calibration, standardization and their usefulness in clinical practice has not been fully elucidated. The aim of this study was to evaluate the accuracy of 2 wearable stretch sensors, C-STRECH® which is used in clinical practice and a novel stretchable capacitor in measuring the respiratory rate. The respiratory rate of 20 healthy subjects was measured by a spirometer with the stretch sensor applied to 1 of 5 locations (umbilicus, lateral abdomen, epigastrium, lateral chest, or chest) of their body at rest while they were in a sitting or supine position before or after exercise. The sensors detected the largest amplitudes at the epigastrium and umbilicus compared to other sites of measurement for the sitting and supine positions, respectively. At rest, the respiratory rate of the sensors had an error of 0.06 to 2.39 breaths/minute, whereas after exercise, an error of 1.57 to 3.72 breaths/minute was observed compared to the spirometer. The sensors were able to detect the respiratory rate of healthy volunteers in the sitting and supine positions, but there was a need for improvement in detection after exercise.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3