Accuracy of Estimated Fetal Weight by Ultrasound Versus Leopold Maneuver

Author:

Lunardhi Alicia1,Huynh Kimberly1,Lee Derek2,Pickering Trevor A.3,Galyon Kristina D.4,Stohl Hindi E.4

Affiliation:

1. Department of Obstetrics and Gynecology, Harbor-UCLA Medical Center, Torrance, CA

2. Division of Maternal Fetal Medicine, Department of OB/GYN at Albany Medical Center, Albany, NY

3. Department of Population and Public Health Sciences, Keck School of Medicine, University of Southern California, Los Angeles

4. Division of Maternal Fetal Medicine, Department of Obstetrics and Gynecology, Harbor-UCLA Medical Center, David Geffen School of Medicine at UCLA, Torrance, CA

Abstract

Abstract Estimated fetal weight (EFW) is frequently used for clinical decision-making in obstetrics. The goals of this study were to determine the accuracy of EFW assessments by Leopold and ultrasound and to investigate any associations with maternal characteristics. Postgraduate years 1 and 2 obstetrics and gynecology resident physicians from Harbor-UCLA Medical Center from 2014 to 2020 performed EFW assessments on 10 preterm (<37 weeks' gestational age) fetuses by ultrasound biometry and 10 full-term (≥37 weeks' gestational age) fetuses by ultrasound biometry and Leopold maneuver. Assessments were included if the patients delivered within 2 weeks of the assessments. One thousand six hundred ninety-seven EFW assessments on 1183 patients performed by 33 residents were analyzed; 72.6% of sonographic full-term EFWs, 69% of Leopold full-term EFWs, and 61.5% of sonographic preterm EFWs were within 10% of the neonatal birth weight (BW). The lowest estimation error in our study occurred when actual BW was 3600 to 3700 g. After adjusting for BW, residents were found to have lower accuracy when the mother had a higher body mass index (BMI) for full-term estimation methods (Leopold and ultrasound, β = 0.13 and 0.12, P = 0.001 and 0.002, respectively). Maternal BMI was not related to estimation error for preterm fetuses (β = 0.01, P = 0.75). Clinical and sonographic EFW assessments performed by obstetrics and gynecology junior residents are within 10% of neonatal BW much of the time. In our cohort, they tended to overestimate EFWs of lower-BW infants and underestimate EFWs of higher-BW infants. Accuracy of full-term EFW assessments seems to decrease with increasing maternal BMI.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Reference28 articles.

1. Estimation of fetal weight with the use of head, body, and femur measurements—a prospective study;Am J Obstet Gynecol,1985

2. OP21.05: fetal weight formula can improve the sonographic detection of the SGA fetus: a mathematical model;Ultrasound Obstet Gynecol,2014

3. Antepartum detection of macrosomic fetus: clinical versus sonographic, including soft-tissue measurements;Obstet Gynecol,2000

4. Estimated weight of the term fetus. Accuracy of ultrasound vs. clinical examination;J Reprod Med,1988

5. Clinical and sonographic estimation of fetal weight performed during labor by residents;Am J Obstet Gynecol,2005

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3