Evaluation of Soft-Tissue Hematomas With Real-Time, Contrast-Enhanced Ultrasound

Author:

Kummer Tobias1,Mohn Kelli J.1,Bardwell Abigail J.2,Boyum James H.3

Affiliation:

1. Emergency Medicine

2. Orthopedic Surgery

3. Radiology, Mayo Clinic, Rochester, MN.

Abstract

AbstractIn this study, we investigated the feasibility of using contrast-enhanced ultrasound (CEUS) to detect active hemorrhage in patients presenting with soft-tissue hematomas. Adult patients with clinically suspected, actively bleeding hematomas were prospectively enrolled. Contrast-enhanced ultrasound was used to assess for contrast extravasation. Ultrasound results were compared with those of multidetector computed tomographic (MDCT) imaging, operative findings, and clinical course. Sixteen patients (9 women, 7 men; mean age, 69 [SD, 13] years) were enrolled. Thirteen patients underwent MDCT imaging during their initial visit, and for 11, CEUS and computed tomography (CT) findings were concordant. The remaining patients had a negative CEUS study that was consistent with their clinical course. In 8 patients, CT imaging showed active extravasation (6 arterial, 1 indeterminate, 1 slow venous). Contrast-enhanced ultrasound and CT findings were concordant for all cases of arterial bleeding. For 1 patient, CEUS provided superior diagnostic information by identifying a pseudoaneurysm. The 2 discrepant patient cases had a ≥3-hour delay between CT and CEUS, and in 1 patient, CEUS was limited by body habitus. The second patient had no active bleeding identified in the operating room. Compared with CT, CEUS had a sensitivity and specificity of 75% and 100%, respectively, and positive and negative predictive values were 100% and 71%, respectively. Diagnostic accuracy was 85% in this limited study. Contrast-enhanced ultrasound is a promising alternative to MDCT in select patients and may sometimes provide superior clinical information. Limiting factors are large hematoma size, unfavorable anatomic location, and body habitus.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

General Medicine

Reference34 articles.

1. The changing nature of rectus sheath haematoma: case series and literature review;Int J Surg,2009

2. Rectus sheath hematoma: review of 126 cases at a single institution;Medicine (Baltimore),2006

3. Spontaneous soft tissue hematomas;Diagn Interv Imaging,2015

4. Ultrasound contrast agents: basic principles;Eur J Radiol,1998

5. Microbubbles in medical imaging: current applications and future directions;Nat Rev Drug Discov,2004