Lung–Reporting and Data System 2.0

Author:

Chelala Lydia1,Hossain Rydhwana2,Jeudy Jean2,Nader Ziad3,Kastner Julia2,White Charles2

Affiliation:

1. Department of Radiology, University of Chicago Medicine, Chicago, IL

2. Department of Radiology, University of Maryland Medical Center, Baltimore MD

3. Department of executive education, Paris Dauphine University, Paris, France

Abstract

Purpose: To determine the frequency of malignancy of nonperifissural juxtapleural nodules (JPNs) measuring 6 to < 10 mm in a subset of low-dose chest computed tomographies from the National Lung Cancer Screening Trial and the rate of down-classification of such nodules in Lung-Reporting and Data System (RADS) 2.0 compared with Lung-RADS 1.1. Materials and Methods: A secondary analysis of a subset of the National Lung Screening Trial was performed. An exemption was granted by the Institutional Review Board. The dominant noncalcified nodule measuring 6 to <10 mm was identified on all available prevalence computed tomographies. Nodules were categorized as pleural or nonpleural. Benign or malignant morphology was recorded. Initial and updated categories based on Lung-RADS 1.1 and Lung-RADS 2.0 were assigned, respectively. The impact of the down-classification of JPN was assessed. Both classification schemes were compared using the McNemar test (P < 0.01). Results: A total of 2813 patients (62 ± 5 y, 1717 men) with 4408 noncalcified nodules were studied. One thousand seventy-three dominant nodules measuring 6 to <10 mm were identified. Three hundred forty-eight (32.4%) were JPN. The updated scheme allowed down-classification of 310 JPN from categories 3 (n = 198) and 4A (n = 112) to category 2. We, therefore, estimate a 4.8% rate of down-classification to category 2 in the entire National Lung Screening Trial screening group. Two/348 (0.57%) JPN were malignant, both nonbenign in morphology. The false-positive rate decreased in the updated classification (P < 0.01). Conclusion: This study demonstrates the low malignant potential of benign morphology JPN measuring 6 mm to <10 mm. The Lung-RADS 2.0 approach to JPN is estimated to reduce short-term follow-ups and false-positive results.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Pulmonary and Respiratory Medicine,Radiology, Nuclear Medicine and imaging

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3