Do Pedicle Screws That Terminate in the Costovertebral Joint Compromise Proximal Anchor Fixation in a Dual Growing Rod Construct?

Author:

Henstenburg Jeffrey1,Hori Yusuke2,Rogers Kenneth J.2,Petfield Joseph L.3,Shah Suken A.2,Gabos Peter G.2

Affiliation:

1. Rothman Institute at Thomas Jefferson University, Philadelphia

2. Department of Orthopaedic Surgery, Nemours Children’s Health, Wilmington, DE

3. Department of Orthopaedic Surgery, Penn State Hershey Medical Center, Hershey, PA

Abstract

Introduction: Growing rods (GRs) are used to treat early-onset scoliosis (EOS) recalcitrant to bracing and casting. Proximal anchor pullout, a known complication of GR constructs, can result in spinal cord injury if pedicle screw anchors are placed with a lateral-to-medial trajectory. To mitigate this risk, a more straightforward and potentially safer trajectory may result in screws that terminate within the costovertebral joint (CVJ). We asked, how often does CVJ placement occur and does this technique increase the rate of failure in GR constructs? Methods: We retrospectively reviewed 35 patients with EOS treated with dual GR with >2-year follow-up excluding patients with skeletal dysplasia or history of previous posterior instrumentation. Patient demographics, radiographic parameters, and implant constructs were assessed. Results: Of patients meeting the inclusion criteria, 18/35 (51%) were females with an average age of 7.96 (range: 4.0 to 15.2) years at surgery with a follow-up of 3.7 (range: 2.0 to 7.7) years. Five (14%) patients had idiopathic EOS, 5 (14%) had congenital EOS, 12 (34%) had neuromuscular EOS, 10 (29%) had syndromic scoliosis, and 3 (9%) had another etiology for EOS. Among 195 proximal pedicle screws placed, 19 (10%) terminated within the CVJ, and 13 patients (37%) had at least 1 CVJ screw. Two patients (6%) experienced unilateral proximal pullout. In both patients, the anchors on the affected side included 1 of 2 screws within the CVJ. Both patients had constructs that included 2 screws on the side that pulled out and 3 screws on the side that did not. None of the remaining 17 CVJ screws led to implant failure. Conclusion: Pedicle screw placement within the CVJ is common and does not appear to significantly contribute to proximal screw pullout; however, it may contribute to unilateral implant failure in constructs employing only 2 proximal screws, where 1 of those 2 screws terminates within the CVJ. Construct modifications should be considered in this scenario. Level of Evidence: Level III.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Pediatrics, Perinatology and Child Health

Reference29 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3