Pediatric Lateral Humeral Condyle Fractures: Reliability of a Modified Jakob Classification System and its Impact on Treatment Planning With or Without Arthrography

Author:

Miller Joseph S.12,Weishuhn Luke3,Goodrich Eric4,Patel Jay5,McCarthy James J.1,Mehlman Charles T.1

Affiliation:

1. Division of Pediatric Orthopaedic Surgery, Cincinnati Children’s Hospital Medical Center Cincinnati

2. Ohio University Heritage College of Osteopathic Medicine Dublin, Ohio

3. Division of Orthopaedic Surgery, Beaumont Hospital, Farmington Hills

4. Division of Orthopaedic Surgery, Lake Erie College of Osteopathic Medicine Health, Erie, Pennsylvania

5. Division of Orthopaedic Surgery, McLaren Greater Lansing, Lansing, Michigan

Abstract

Background: Various lateral humeral condyle fracture (LHCF) classification systems have been in use since the 1950s, but limited research exists on their reliability. The most widely utilized, yet un-validated system is that of Jakob and colleagues. The purpose of the current study was to analyze the reliability of a modified Jakob classification system and its value in guiding treatment either with or without arthrography. Methods: Interrater and intrarater reliability studies were performed using radiographs and arthrograms from 32 LHCFs. Radiographs were presented to 3 pediatric orthopaedic surgeons and 6 pediatric orthopaedic surgery residents who were asked to classify the fractures according to a modified Jakob classification system, enunciate their treatment plan, and whether they would utilize arthrography. Classification was repeated within 2 weeks to assess intrarater reliability. The treatment plan using radiographs only and radiographs with arthrography were compared at both rating points. Results: The modified Jakob system had excellent interrater reliability using only radiographs with a kappa value of 0.82 and an overall agreement of 86%. The average kappa for intrarater reliability using only radiographs was 0.88 with a range of 0.79 to 1.00 and an average overall agreement of 91% with a range of 84% to 100%. Interrater and intrarater reliability was poorer using both radiographs and arthrography. On average, arthrography changed the treatment plan in 8% of cases. Conclusions: The modified Jakob classification system proved to be a reliable classification system for LHCFs, independent of arthrography, given the excellent free-marginal multirater kappa values. Level of Evidence: Level III—diagnostic.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Pediatrics, Perinatology and Child Health

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3