Reliability of the Modified Method for Sphericity Deviation Score Using Only the Involved Hip Radiographs in the Patients With Legg-Calve-Perthes Disease

Author:

Kang Michael Seungcheol123,Kak Arnav1,Prasadh Jai Ganesh2,Kim Harry Kwang-Woo12

Affiliation:

1. Scottish Rite for Children

2. Southwestern Medical Center, University of Texas, Dallas, TX

3. Department of Orthopedic Surgery, Asan Medical Center Children’s Hospital, University of Ulsan College of Medicine, Seoul, Republic of Korea

Abstract

Background: The sphericity deviation score (SDS) is a validated radiographic outcome measure that quantifies the severity of the femoral head deformity in the healed stage of Legg-Calve-Perthes disease (LCPD). The current method requires radiographs of both hips regardless of unilateral involvement to standardize radiographic magnification. As LCPD affects the unilateral hip in 85% to 90% of cases, the current method imposes unnecessary radiation exposure to most of the patients and having to exclude patients from research studies who only had unilateral hip radiographs. We thus modified the SDS method to use unilateral hip radiographs. The purpose of this study was to investigate the reliability of the modified SDS method using the radiographs containing only one hip. Methods: This retrospective study involved 40 patients with LCPD with unilateral involvement in the healed stage of LCPD. We modified the SDS measurement method by using the distance between the teardrop and the lateral acetabulum for magnification correction and providing a clear anatomic description of reference points on the femoral head. Three independent observers performed measurements using radiographs containing the affected hip only (modified method) and both hips (conventional method). The intraclass correlation (ICC) estimates were calculated. To verify clinical relevance, the correlation of the SDS with the Stulberg classification and hip range of motion (ROM) were also investigated. Results: Measurements using the modified SDS showed excellent inter-/intra-observer ICCs (0.903 to 0.978). The ICCs between the modified and conventional methods were also excellent: 0.940 to 0.966 within the same observer and 0.897 to 0.919 between different observers. The modified SDS showed moderate-to-strong correlations with the Stulberg classification (Spearman ρ=0.650) and hip ROM (Pearson r=−0.661). Conclusion: The modified SDS measurement method showed excellent inter-/intra-observer reliability and moderate-to-strong correlations with the Stulberg classification and hip ROM. This method will help reduce unnecessary radiation exposure in patients with unilateral LCPD and prevent the exclusion of patients with unilateral radiographs from future research studies. Level of Evidence: Level III—diagnostic study.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Orthopedics and Sports Medicine,General Medicine,Pediatrics, Perinatology and Child Health

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3