Bivalirudin Monitoring in Pediatric Ventricular Assist Device and Extracorporeal Membrane Oxygenation: Analysis of Single-Center Retrospective Cohort Data 2018–2022

Author:

Engel Elissa R.12,Perry Tanya13,Block Mary4,Palumbo Joseph S.124,Lorts Angela13,Luchtman-Jones Lori124

Affiliation:

1. Department of Pediatrics, University of Cincinnati College of Medicine, Cincinnati, OH.

2. Cancer and Blood Diseases Institute, Division of Hematology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH.

3. The Heart Institute, Division of Cardiology, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH.

4. Cancer and Blood Diseases Institute, Division of Hematology, Hemostasis and Thrombosis Laboratory, Cincinnati Children’s Hospital Medical Center, Cincinnati, OH.

Abstract

Objectives: The activated partial thromboplastin time (aPTT) is the most frequently used monitoring assay for bivalirudin in children and young adults on mechanical circulatory support including ventricular assist devices (VADs) and extracorporeal membrane oxygenation (ECMO). However, intrinsic variability of the aPTT complicates management and risks bleeding or thrombotic complications. We evaluated the utility and reliability of a bivalirudin-calibrated dilute thrombin time (Bival dTT) assay for bivalirudin monitoring in this population. Design: Retrospective analysis of clinical data (including aPTT, dilute thrombin time [dTT]) and results of residual plasma samples from VAD patients were assessed in two drug-calibrated experimental assays. One assay (Bival dTT) was validated for clinical use in VAD patients, and subsequently used by clinicians in ECMO patients. Pearson correlation and simple linear regression were used to determine R 2 correlation coefficients between the different laboratory parameters using Statistical Package for Social Sciences (Armonk, NY). Setting: ICUs at Cincinnati Children’s Hospital Medical Center. Subjects: Children on VAD or ECMO support anticoagulated with bivalirudin. Interventions: None. Measurements and Main Results: One hundred fifteen plasma samples from 11 VAD patients were analyzed. Both drug-calibrated experimental assays (anti-IIa and Bival dTT) showed excellent correlation with each other (R 2 = 0.94) and with the dTT (R 2 = 0.87), but poor correlation with aPTT (R 2 = 0.1). Bival dTT was selected for validation in VAD patients. Subsequently, clinically ordered results (105) from 11 ECMO patients demonstrated excellent correlation between the Bival dTT and the standard dTT (R 2 = 0.86) but very poor correlation with aPTT (R 2 = 0.004). Conclusions: APTT is unreliable and correlates poorly with bivalirudin’s anticoagulant effect in ECMO and VAD patients. A drug-calibrated Bival dTT offers superior reliability and opportunity to standardize results across institutions. Additional studies are needed to determine an appropriate therapeutic range and correlation with clinical outcomes.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3