Design of medical tympanostomy conduits with selective fluid transport properties

Author:

Patel Haritosh12ORCID,Pavlichenko Ida12ORCID,Grinthal Alison1,Zhang Cathy T.1ORCID,Alvarenga Jack12ORCID,Kreder Michael J.1,Weaver James C.12,Ji Qin2ORCID,Ling Christopher W. F.2ORCID,Choy Joseph2ORCID,Li Zihan2ORCID,Black Nicole L.12ORCID,Bispo Paulo J. M.34ORCID,Lewis Jennifer A.12ORCID,Kozin Elliott D.45,Aizenberg Joanna126ORCID,Remenschneider Aaron K.45ORCID

Affiliation:

1. Harvard John A. Paulson School of Engineering and Applied Sciences, Harvard University, Boston, MA 02134, USA.

2. Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA.

3. Department of Ophthalmology, Massachusetts Eye and Ear, Boston, MA 02114, USA.

4. Harvard Medical School, Harvard University, Boston, MA 02115, USA.

5. Department of Otolaryngology–Head and Neck Surgery, Massachusetts Eye and Ear, Boston, MA 02114, USA.

6. Department of Chemistry and Chemical Biology, Harvard University, Cambridge, MA 02138, USA.

Abstract

Implantable tubes, shunts, and other medical conduits are crucial for treating a wide range of conditions from ears and eyes to brain and liver but often impose serious risks of device infection, obstruction, migration, unreliable function, and tissue damage. Efforts to alleviate these complications remain at an impasse because of fundamentally conflicting design requirements: Millimeter-scale size is required to minimize invasiveness but exacerbates occlusion and malfunction. Here, we present a rational design strategy that reconciles these trade-offs in an implantable tube that is even smaller than the current standard of care. Using tympanostomy tubes (ear tubes) as an exemplary case, we developed an iterative screening algorithm and show how unique curved lumen geometries of the liquid-infused conduit can be designed to co-optimize drug delivery, effusion drainage, water resistance, and biocontamination/ingrowth prevention in a single subcapillary–length-scale device. Through extensive in vitro studies, we demonstrate that the engineered tubes enabled selective uni- and bidirectional fluid transport; nearly eliminated adhesion and growth of common pathogenic bacteria, blood, and cells; and prevented tissue ingrowth. The engineered tubes also enabled complete eardrum healing and hearing preservation and exhibited more efficient and rapid antibiotic delivery to the middle ear in healthy chinchillas compared with current tympanostomy tubes, without resulting in ototoxicity at up to 24 weeks. The design principle and optimization algorithm presented here may enable tubes to be customized for a wide range of patient needs.

Publisher

American Association for the Advancement of Science (AAAS)

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Flexible liquid-diode microtubes from multimodal microfluidics;Proceedings of the National Academy of Sciences;2024-07-03

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3