Effects of postural changes on measured intraocular pressure and repeatability of PT-100 tonometer and agreement with applanation and indentation tonometry

Author:

Tairi Ahmed I.ORCID,Ogbuehi Kelechi C.ORCID,Zafar HamayunORCID,King Matthew D.ORCID,Obinwanne Chukwuemeka J.ORCID,Mashige Khathutshelo P.ORCID,Osuagwu Uchechukwu L.ORCID

Abstract

Background: Repeatability and validity are important components of precision in any measurement system.Aim: This study aimed to determine the effect of change in head and neck position and body posture on the repeatability of intraocular pressure (IOP) measurements with PT-100 non-contact tonometer and compare with Goldmann, PT-100 and Schiøtz tonometer readings.Setting: Optometry clinic, Saudi Arabia.Methods: The IOP was measured in one selected eye of 84 healthy participants (mean aged 21.9 ± 2.0 years) using PT-100 in three head and body positions, Goldmann tonometer and Schiøtz on two separate visits, in a randomised fashion. Central corneal thickness (CCT) was measured using an ultrasound pachymeter. The repeatability, agreement and correlations between CCT and IOP differentials were assessed.Results: The IOP measured in three head and body positions with the PT-100 were similar and comparable to Goldmann IOPs in sessions one and two with 74% and 86% of PT-100 measurements within ±3 mmHg of the Goldmann tonometry, respectively, for sessions one and two. The Schiøtz tonometer-measured IOP was higher than the Goldmann IOPs (p  0.05) with 60% and 44% of Schiøtz IOPs within ±3 mmHg of the Goldmann tonometer IOP in sessions one and two, respectively. The limits of repeatability and reproducibility were best with the PT-100 and worst with the Schiøtz tonometer. The mean CCT (552±36 µm) was negatively correlated with differences between Goldmann and both PT-100 and Schiøtz-measured IOP.Conclusion: Postural changes did not affect the validity and repeatability of PT-100 readings. PT-100 measurements were interchangeable with Goldmann tonometer. Schiøtz overestimated Goldmann IOP in thicker corneas more than the PT-100.

Publisher

AOSIS

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3