A microscopic analysis of single-use versus multi-use phacoemulsification tubing in maintaining sterility and patient safety

Author:

Ndlovu Lungile T.ORCID

Abstract

Background: The Pietermaritzburg (PMB) complex in South Africa does not have a uniform protocol regarding reuse of phacoemulsification tubing. Each hospital in the complex has its own guideline, based on manufacturer recommendation and cost-saving measures. There is no definitive scientific evidence proving that reusing phaco tubing will harm patients.Aim: To assess if phacoemulsification tubing remains sterile during sequential phacoemulsification.Setting: The study was conducted at Edendale Hospital and Greys Hospital in PMB. Greys Hospital has a single-use policy and at Edendale policy, multi-use of tubings is allowed.Methods: This was an observational descriptive prospective study observed over 4 months. Routine phacoemulsification was carried out at each hospital as per hospital guidelines. At the end of the surgery, the tips of the tubing were cut off, placed in a standard specimen container and sent to the laboratory for culture and microscopy. Results were compared and two unused tubings were also analysed as controls.Results: A total of 26 single-use tubings were analysed and it was found that 46.2% grew no organisms; 19.2% grew Bacillus species; other microorganisms were in less than 1% of tubings. A total of 41 multiple-use tubings were sent for analysis. Forty one and a half percent grew no organisms; 17.1% tubings grew Bacillus species. Other microorganisms were found in less than 5% of tubings. Unused tubings did not grow any microorganism.Conclusion: A p value less than 0.05% was accepted as statistically significant. Comparing the two hospitals, tubings which grew no organisms were 46.2% (single-use) versus 41.5% (multiple-use). This gives a statistically non-significant p value of 0.70. Tubings which grew Bacillus species were 19.2% (single-use) versus 17.1% (multiple-use) (p = 0.83). Other microorganisms also showed a p value of 0.76. This implies that phacoemulsification tubing is significantly contaminated after just one use. Although no statistical difference was found between the two groups, a contamination rate of over 40% is of great concern. There are contributing factors which may have influenced this result. In our setting, phaco tubing does not seem to remain sterile after cataract surgery. Further research needs to be carried out in order to gain more insight into patient safety.

Publisher

AOSIS

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3