Evaluation of fixed-panel, multicolour ClearLLab 10C at an academic flow cytometry laboratory in Johannesburg, South Africa

Author:

Glencross Deborah K.ORCID,Swart LeanneORCID,Pretorius MelanieORCID,Lawrie DeniseORCID

Abstract

Background: Flow cytometric immunophenotyping is well established for the diagnosis of haematological neoplasms. New commercially available systems offer fixed, pre-aliquoted multi-parameter analysis to simplify sample preparation and standardise data analysis.Objective: The Beckman Coulter (BC) ClearLLab™ 10C (4-tube) system was evaluated against an existing laboratory developed test (LDT).Methods: Peripheral blood and bone marrow aspirates (n = 101), tested between August 2019 and November 2019 at an academic pathology laboratory in Johannesburg, South Africa, were analysed. Following daily instrument quality control, samples were prepared for LDT (using 20 2–4-colour in-house panels and an extensive liquid monoclonal reagent repertoire) or ClearLLab 10C, and respectively analysed using in-house protocols on a Becton Dickinson FACSCalibur, or manufacturer-directed protocols on a BC Navios. Becton Dickinson Paint-a-Gate or BC Kaluza C software facilitated data interpretation. Diagnostic accuracy (concordance) was established by calculating sensitivity and specificity outcomes.Results: Excellent agreement (clinical diagnostic concordance) with 100% specificity and sensitivity was established between LDT and ClearLLab 10C in 67 patients with a haematological neoplasm and 34 participants with no haematological disease. Similar acceptable diagnostic concordance (97%) was noted when comparing ClearLLab 10C to clinicopathological outcomes. Additionally, the ClearLLab 10C panels, analysed with Kaluza C software, enabled simultaneous discrimination of disease and concurrent background myeloid and lymphoid haematological populations, including assessing stages of maturation or sub-populations.Conclusion: ClearLLab 10C panels provide excellent agreement to existing LDTs and may reliably be used for immunophenotyping of haematological neoplasms, simplifying and standardising sample preparation and data acquisition. 

Publisher

AOSIS

Subject

Clinical Biochemistry,Medical Laboratory Technology,Public Health, Environmental and Occupational Health

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3