Considerations for the verification of volumetric modulated arc therapy-planned dose distributions

Author:

Strauss LourensORCID,Shaw WilliamORCID

Abstract

Background: Volumetric modulated arc therapy (VMAT) is the standard of care for many clinical indications, but should only be considered with proper technical support and quality assurance (QA) in place. Despite the high accuracy of VMAT systems, errors can be present and adequate verification is required. Dosimetric VMAT verification systems have a broadly similar analysis philosophy. However, many factors influence the analyses and the subsequent QA outcome, based on which the plan will pass or fail.Aim: This study investigated various factors that influence the dosimetric impact and detectability of known linac component deviations on VMAT QA, including geometries, tissue densities, gamma criteria and dose–volume differences.Setting: Universitas Hospital (Annex), Bloemfontein, South Africa.Methods: Deliberate multi-leaf collimator (MLC)-bank offsets were introduced on four different VMAT plans of the prostate, nasopharynx and brain. Measured reference dose sets were compared to measured QA results, using the IBA Dolphin© detector and Compass© software for three dosimetric scenarios. Gamma pass rates over a range of criteria from 1%/2-mm to 4%/4-mm in the total volumes and per structure, as well as dose–volume differences were studied.Results: Gamma tests in the total patient/phantom did not sufficiently detect errors. The calculation media did not influence the QA outcome greatly. However, the detection geometry affected the results. Per structure gamma analyses provided superior error detection, although still missed some clinically relevant differences. The addition of dose–volume analyses highlighted several important errors.Conclusion: Volumetric modulated arc therapy using only total volume gamma analyses can easily overlook clinically relevant errors. The choice of gamma criterion is crucial. Verification with at least a per structure gamma test in combination with dose–volume checks is recommended, especially in small target volume cases.

Publisher

AOSIS

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3