Point-of-Care Glucose and Lipid Profile Measures Using a Human Point-of-Care Device in Mouse Models of Type 2 Diabetes Mellitus, Aging, and Alzheimer Disease

Author:

Smyth Brendan J1,Polaski Rachel S2,Safer Anton3,Boettcher Flint A1,Konrad-Martin Dawn2,Gratton Michael Anne1

Affiliation:

1. Department of Otolaryngology–Head and Neck Surgery, Washington University, St Louis, Missouri

2. VA RR&D National Center for Rehabilitative Auditory Research, VA Portland Health Care System, Portland, Oregon

3. Institute of Global Health (HIGH), Heidelberg University, Heidelberg, Germany

Abstract

A point-of-care (POC) device to measure mouse glucose and lipid profiles is an important unmet need for cost-effective, immediate decision making in research. We compared metabolic analyte profiles obtained using a human clinical POC device with those from a veterinary laboratory chemical analyzer (LCA). Unfasted terminal blood samples were obtained by cardiac puncture from C57Bl/6J mice used in a diet-induced obesity model of type 2 diabetes mellitus; age-matched C57Bl/6J controls; a transgenic mouse model of Alzheimer's disease on a C57BL/6J background (16 wk old); and aged C57BL/6J mice (24 to 60 wk old). Aliquots of the blood were immediately assayed onsite using the POC device. Corresponding serum aliquots were sent analyzed by LCA. Measures from the POC and LCA devices were compared by using the Bland–Altman and Passing–Bablok methods. Of a total of 40 aliquots, LCA results were within reported reference ranges for each model. POC results that fell beyond the device range were excluded from the analyses. The coefficient of determination and Passing–Bablok analysis demonstrated that POC glucose and HDL had the best agreement with LCA. The Bland–Altman analysis found no value-dependent bias in glucose and no significant bias in HDL. The remaining lipid analytes (cholesterol and triglyceride) showed significant bias. Until an improved, validated mouse POC device with lipid profile capability is available, the POC device that we tested appears adequate for screening glucose and HDL in mouse blood. Disadvantages of this clinical POC device are the narrow human ranges relative to ranges found in mice and its limited precision as compared with the LCA. This study demonstrates that when the samples are within the device range limits, this human POC device can accurately track metabolic syndrome and be used to compare patterns in glucose and HDL.

Publisher

American Association for Laboratory Animal Science

Subject

Animal Science and Zoology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3