Abstract

Validated glass bead sterilization protocols to effectively sterilize rodent surgical instruments after bacterial exposure (for example, cecal contamination) are lacking. To refine current approaches, we added either a multienzyme detergent, neutral pH detergent, or chlorhexidine scrub step before glass bead sterilization of forceps or needle drivers exposed to cecal contents. We exposed sets of forceps and needle drivers to cecal contents, which were then air dried for 3 min. Immediately after, the instruments were wiped several times with a clean, dry paper towel. The contaminated tips were soaked in either a multienzyme or neutral pH detergent (t = 5 min), chlorhexidine scrub (t = 2 min), or no pretreatment solution. To further increase debris removal, instruments (from all groups) were brushed using a clean toothbrush. The nonpretreatment instruments were briefly soaked in saline before brushing. After being rinsed with sterile water, all instruments were exposed to a glass bead sterilizer for 60 s at 500 °F (260 °C). Sets were then swabbed for bacterial culturing. Swabs were plated onto either sheep blood agar (n = 23) or chocolate agar (n = 20) for aerobic culturing or Brucella agar (n = 20) for anaerobic culturing. A subset of instruments was sampled to determine organic material presence after treatment using an ATP luminometer (n = 21). Multiple agar types and bioluminescence were used to more deeply evaluate tool sterility and to differentiate the relative effectiveness of each protocol. From the saline group, only one pair of forceps yielded growth on Brucella agar, and 2 pairs yielded growth on chocolate agar. No other bacterial growth was observed. The use of a pretreatment agent also lowered overall organic contamination levels in needle drivers compared with using only saline. These results indicate that brushing instruments to mechanically remove debris from instruments is paramount to ensure sterility. However, a best practice would be to also use one of the pretreatment options used in this study.

Publisher

American Association for Laboratory Animal Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3